6  Accessories 

 
Included 

Article No  

DV-Win PC software including USB cable 

 

Built-in Tap Changer Control Unit 

 

Tap Changer Control cable 5 m 

 

Mains power cable 

 

Ground (PE) cable 

 

 

 
Recommended 

Article No  

H winding test cable 5 m, three-phase connection, with TTA clamps

 

HC-05-03MCWC

 

H winding test cable extension, 5 m, shielded 

HE-05-03MCWC

 

X winding test cable, 5 m, three-phase connection, with TTA clamps 

XC-05-03FCWC

 

X winding test cable extension, 5 m, shielded 

XE-05-03FCWC

 

Cable bag 

CABLE-BAG-01

 

 

 

 
Optional 

Article No  

H winding test cable extension, 10 m, shielded 

HE-10-03MCWC

 

X winding test cable extension, 10 m, shielded 

XE-10-03FCWC

 

H winding test cable extension, 15 m, shielded 

HE-15-03MCWC 

X winding test cable extension, 15 m, shielded 

XE-15-03FCWC

 

H winding test cable 3 m, 3~ connection, with TTA clamps

 

HC-03-03MCWC

 

X winding test cable 3 m, 3~ connection, with TTA clamps

 

XC-03-03FCWC

 

H winding test cable 10 m, 3~ connection, with TTA clamps

 

HC-10-03MCWC

 

X winding test cable 10 m, 3~ connection, with TTA clamps

 

XC-10-03FCWC

 

H winding test lead, 3 m, 1~ connection, with TTA clamps 

HC-03-01MCWC

 

X winding test lead, 3 m, 1~ connection, with TTA clamps 

XC-03-01FCWC

 

H winding test lead, 5 m, 1~ connection, with TTA clamps 

HC-05-01MCWC

 

X winding test lead, 5 m, 1~ connection, with TTA clamps 

XC-05-01FCWC

 

Cable plastic case 

– medium size 

CABLE-CAS-02 

Cable plastic case with wheels 

– medium size 

CABLE-CAS-W2 

Transport case 

HARD-CASE-D1 

Built-in thermal printer 

PRINT-112-00

 

Bluetooth communication module 

BLUETOOTH-00 

Inverter 12 V DC to 230 V AC, 50 Hz 

IN650-12-230

 

Verification Calibrator TRTC 

TRTC-05-4800

 

H winding test lead, 1 m, 3~ connection with banana plugs 

HC-01-03MCBP 

X winding test lead, 1 m, 3~ connection with banana plugs 

XC-01-03FCBP 

 

IBEKO Power AB 2013 

 

This  Manual  is  a  publication  of  IBEKO  Power  AB,  181  50  Lidingö,  Sweden.  These  documents  are  protected  by 
Swedish  Copyright  law  and  international  contracts  as  intellectual  property  of  the  IBEKO  Power  AB.  The  documents 
contain confidential information of  IBEKO Power  AB  which is protected by  patent, copyright, trademarks or otherwise 
as inventions, trademarks or creations of IBEKO Power AB. The reproduction, duplication, transmission or use of these 
documents or its contents is not permitted without express prior written consent of the IBEKO Power AB. 
IBEKO Power AB shall not be liable for any incidental or consequential damages resulting from the performance or use 
of  this  document  or  its  product.  This  document  has  undergone  extensive  technical  approval  before  being  released. 
IBEKO  Power  AB  reviews  this  document  at  regular  intervals,  and  includes  appropriate  amendments  in  subsequent 
issues.  While  every  effort  has  been  made  to  keep  the  information  herein  as  accurate  and  up  to  date  as  possible, 
IBEKO  Power  AB  assumes  no  responsibility  for  errors  or  omissions  or  for  damages  resulting  from  the  use  of  the 
information  contained  herein.  IBEKO  Power  AB  cannot  take  over  liability  resulting  in  any  way  from  the  use  of  this 
document  or  parts  thereof.  The  product  information,  pictures,  drawings  and  all  technical  data  contained  within  this 
manual are not contractually binding and IBEKO Power AB reserves the right to make modifications at any time to the 
technology and/or configuration without prior notice. 
Insofar as any information, software or documentation is made available, any liability for defects as to quality or title of 
the  information,  software  and  documentation  especially  in  relation  to  the  correctness  or  absence  of  defects  or  the 
absence of claims or third party rights or in relation to completeness and/or fitness for purpose are excluded except for 
cases involving willful misconduct or fraud. 
In case of a disagreement between the translation and the original English version of this Manual, the original English 
version will prevail.

 

Summary of Contents for TRT30C

Page 1: ...TRT30C THREE PHASE TRANSFORMER TURNS RATIO TEST INSTRUMENT Manual ...

Page 2: ...ameters 10 4 Error Messages 13 4 1 Error Message Excitation current too high 13 4 2 Error Message Turns ratio too low 13 4 3 Error Message Malfunction 13 4 4 Error Message Error printer 14 4 5 Error Message Check paper 14 4 6 Error Message USB flash drive 14 4 7 Error Message Connect both neutral cables 14 4 8 Error Message Emergency Stop 15 4 9 Error Message Connections 15 5 Technical Data 16 5 1...

Page 3: ...erms in this Manual These terms may appear in the Manual WARNING Warning statements identify conditions or practices that could result in injury or loss of life CAUTION Caution statements identify conditions or practices that could result in damage to this product or to other property Terms on the Device The following warning terms used in this document may appear on the device WARNING Warning ind...

Page 4: ...he TRT30C Hazardous voltages exist on the terminals of the TRT30C when the Red LED is lit Never assume that the connections are safe even if this LED is off Switch off and unplug the TRT30C before touching the connections particularly if a fault is suspected Before putting the TRT30C into operation check the test set for any visible damage Do not operate the TRT30C under wet or moist conditions co...

Page 5: ...erference in which case the user may be required to take adequate measures Il s agit d un produit de classe A Dans un environnement domestique ce produit peut provoquer des interférences radio auquel cas l utilisateur peut être amené à prendre des mesures adéquates 1 3 Measurement Category The TRT30C is intended to be used for measurements in Measurement Category I CAT I for voltages up to 250V Th...

Page 6: ...ry side and measures the induced voltage at the transformer s secondary side If the test object is a three phase transformer or a three phase autotransformer the TRT30C can apply either three single phase test voltages in turns or a true three phase test voltage to the transformer primary windings Three induced voltages at the transformer s secondary side are measured Please note that any uses of ...

Page 7: ...the TRT30C is separated from the mains power supply 2 Protective Earth Connector For protection against parasitic currents or voltages always connect the TRT30C protective earth connector to the protective ground PE Use only the original cable For safety reasons always establish this connection before establishing any other connection and remove this connection as the very last step 3 Operator Con...

Page 8: ...arted Red LED Lights continuously in case of an operational error Lights continuously when a test is started and a test voltage is applied 4 H and X Terminals H cable terminal The terminal for connecting the H test cable X cable terminal The terminal for connecting the X test cable 5 Emergency Stop Turns off output voltage in case of an emergency 6 Interface and Flash Drive Connectors Interface Th...

Page 9: ...ing situations Cable test leads are terminated with the specially adjusted clips The colors and markings of the test cables are shown in table 1 Table 1 Test lead colors and markings If the primary neutral connection does not exist the 1N H0 N lead should be left isolated from the transformer i e the test object and the other connection leads It must be placed in such a way that it is completely i...

Page 10: ...hidden Only true three phase test True 3 phase test using 3 phase voltage AUTO hidden hidden Autotransformer menu See table 4 Press ENTER to choose one of the available options in the configuration menu 1 If the vector group is selected the TRT30C will perform both the true three phase test by applying true three phase test voltage and the phase by phase test by applying single phase test voltages...

Page 11: ...on calculation is enabled the following menu is displayed for entering the name plate voltages and the tap changer positions If the name plate voltages are not entered the TRT30C will perform the test and display the results but it will not calculate or display the turns ratio deviation After the name plate voltages and tap changer position s are entered press ENTER to confirm selection The next d...

Page 12: ...the transformer Test Record can contain the results of all tap changer positions or the complete results obtained from one transformer Note Manual selection of record reading will delete results from the existing memory locations Once these parameters are defined pressing ENTER changes the status to the READY state If one of the values has to be changed press STOP to return to the previous menu Th...

Page 13: ...repeated with a lower test voltage Another reason for an excitation current which is too high is that the connections are reversed If there are no connections errors found there may be a short circuit within the transformer itself 4 2 Error Message Turns ratio too low This message is displayed if the turns ratio of the transformer under the test is lower than 0 8 In this case the user should check...

Page 14: ... Check paper is displayed if the printer is out of paper 4 6 Error Message USB flash drive If the USB flash drive is not plugged in while trying to export the data the error message shown below will be displayed 4 7 Error Message Connect both neutral cables If one of the neutral cables is not connected to the autotransformer under test during AVGD test the error message shown below will be display...

Page 15: ...he Emergency stop button by rotating it clockwise 4 9 Error Message Connections The Error message Connections is displayed if the H or X cables are not connected properly to the TRT30C There are also green LED lights near the connectors which light up to indicate that these connectors are connected properly Figure 4 9 Error message Connections Figure 4 8 Error message Emergency stop ...

Page 16: ...125 1000 3999 0 125 4000 15000 0 25 80 V AC 0 8 999 0 125 1000 3999 0 25 4000 15000 0 5 40 V AC 0 8 999 0 125 1000 3999 0 25 4000 15000 0 5 8 V AC Excitation Current Range 0 2 A Typical Excitation Current Accuracy 0 25 500 μA Guaranteed Excitation Current Accuracy 0 25 1 mA Excitation Current Resolution 0 9 9999 mA 0 1 μA 10 99 999 mA 1 μA 100 999 99 mA 10 μA 1 2 A 100 μA Phase Angle Range 360 Deg...

Page 17: ...a M T030CN 203 EN 17 5 6 Applicable Standards Installation overvoltage category II Pollution degree 2 Safety LVD 2006 95 EC CE Conform Standard EN 61010 1 2001 EMC Directive 2004 108 EC CE Conform Standard EN 61326 1 2006 ...

Page 18: ...KO Power AB 181 50 Lidingö Sweden These documents are protected by Swedish Copyright law and international contracts as intellectual property of the IBEKO Power AB The documents contain confidential information of IBEKO Power AB which is protected by patent copyright trademarks or otherwise as inventions trademarks or creations of IBEKO Power AB The reproduction duplication transmission or use of ...

Page 19: ... Manufacturer Contact Information M T030CN 203 EN 19 Manufacturer Contact Information IBEKO POWER AB Box 1346 181 25 Lidingö Sweden Fax 46 8 731 77 99 E Mail support dv power com Website http www dv power com ...

Reviews: