27
RMO600
Error Messages
10.3 Error Message "I x R > 2,5V"
This message is displayed if during the test the voltage at the test object exceeds
2.5V. In this case reduce the test current and repeat the test.
10.4 Error Message "Overheat"
This message is displayed when RMO600’s operating temperature rises too
high due to a high ambient temperature or, despite the duty cycle time control, too
many high current tests were performed in too short of a time.
In this case, wait for the test set to cool down and repeat the test.
10.5 Error Message "Malfunction"
If this message is shown on the display, or if RMO600 cannot be operated
anymore at all, a serious internal error occurred.
Please do not open RMO600 by yourself. Contact the IBEKO POWER AB (refer
to section ”Manufacturer Contact Information”).
10.6 Error Message "Mains Voltage < 90V"
This message is displayed when RMO600’s mains voltage is below 90 V.
In this chase to remove the status message you must restart RMO600.
Figure 10-3:
Error message
"I x R > 2.5V"
Figure 10-4:
Error message
"Overheat"
Figure 10-5:
Error message
"Malfunction"
Figure 10-6:
Error message
"Mains Voltage < 90V"