DC AirCube 500 - 10
Part No 94156
Th
e DC AirCube 500 aircleaner is intended for cleaning
the air in a work area and is intended for use as a compli-
ment to spot extraction. Air is passed through a combina-
tion prefi lter and a microfi lter. Th
e microfi lter is a HEPA
13 fi lter separates particles to 99.95%. Th
e pre- fi lter
separates the majority of the course particles and thereby
prolonging the life of the microfi lter.
When a loss of suction capacity is experienced the pre-
fi lter should be changed. If the suction capacity does not
increase after the pre-fi lter change then the Hepa fi lter
should also be changed.
Description
Operation
Connect the machine to a suitable power source accor-
ding to the specifi cation of the machine. When using an
extension cable with the machine, ensure that the con-
nection is water tight and the extension cable is suitably
rated.
Th
e DC AirCube 500 aircleaner has two speed settings
which allows for economical running, for example during
the night
.
Th
e fan has two speed settings which allow for economi-
cal running, for example during the night.
Th
e DC AirCube 500 can also be used to discharge air
from work places which must be kept under negative
pressure. A 125 mm hose can be attached to the fan out-
let where necessary.
NOTE: When using a long tube or covering the outlet,
the warning light (fi lter light) can be lit.
Check when changing the fi lter that the outlet is free
(warning light)
.
Optinal power outlet 240 V 1200 W.