e DC 3800c/a is stable, tough and reliable and particularly
suited to spot extraction where plenty and easy dust is crea-
ted. DC 3800c/a is suitable in many diff erent applications
ie welding, grinding, sanding and cleanup.
Th
e DC 3800c/a is driven by 2 single phase, two stage
fans.
Th
e extraction system functions with negative pressure (va-
cuum) that draws the air through suction casings/nozzles,
hose system, separator and fi lter system. Coarse separation
of dust occurs in the units cyclone which is a highly effi
cient
separator for larger particulate. Th
e fi ne dust is separated and
contained by the fi lter system. Th
ere is a jacket mounted at
the top of the fi lter cartridge protecting it from the dust as it
enters the cyclone from the hose. Reverse pulse fi lter cleaning
gives long fi lter life and a consistently high suction capacity.
Th
e machine is equipped with a HEPA fi lter.
DC 3800c:
Material which has been extracted and separated is collected
in a 20 l plastic sack. Th
e sack can be removed with a simple
hand grip. Th
e collected material is easily handled in this
way for disposal or recycling.
Description
Operation
Connect the unit to a suitable power source, note require-
ments on the ID plate. If an extension cord is to be used,
only waterproof cords are acceptable.
Th
e DC 3800c/a is equipped with a fi lter indication lamp
that indicates when the fi lter needs cleaning or changing.
Th
e fi lter is generally cleaned once or twice daily during
normal continuous operation. Th
e unit must be in operation
to perform fi lter cleaning. Loose the tube from the suction
pipe and press the plastic cage against the black stop head
on the exhaust channel
so that maximum pressure is cre-
ated in the cyclone.
Open the port on the side of the unit three to six times. Th
is
reverse pulse of air cleans the fi lter.
DC 3800c:
Th
e plastic sack should be changed only after the fi lter has
been cleaned. Th
e sack should be changed when the dust
level is about 5 cm under the foot valve. Th
e plastic sack
should be sealed after removal from the machine.
Use only original plastic sacks
DC 3800a
Th
e container under the cyclone should be emptied when
it is fi lled to ca 2/3..