DC 3800 Stat - 10
Part No 9443-A
Technical Data
50 Hz/60 Hz
HxWxL
fl
oorconstruction
1400x400x860 mm
HxWxL wallconstruction
1440x400x790 mm
Weight
50 kg/50 kg
Inlet
50 mm/
50 mm
Collection in bag/container
30 l/40 l
Max Temp
130°/130°
Flow, max
260 m
3
/h/320 m
3
/h
Neg. pressure, max
28 kPa/30 kPa
Power consumption
2.2 kW/3 kW
Manual reverse pulse
fi
lter cleaning
Fine
fi
lter polyester, area
1.8 m
2
1.8
m
2
Degree of separation
> 99,9 %/> 99,9 %
A
fi
ne
fi
lter, polyester (Part No 42025), is mounted in the
machine. A HEPA
fi
lter is available as optional equipment.
Soundlevel
<75 dB(A)/<75 dB(A)
Filter Cleaning with Reverse Pulse
Compressed air
4 l/s, 4 bar
Connection, hose
6/8 mm
El connection
24 V DC, 12 W
kPa
20
10
100
200
300
400
m
3
/h
500
Vacuum producer
capacity
DC 3800
2.5 kW 50 Hz
DC 3800 3.0 kW 60 Hz
The DC 3800 Stationary is a dust extractor suitable
for the extraction of dust, powders and chips and
also for cleaning.
The
fi
lter is cleaned with air pulse against the
fl
ow of extracted air. This arrangement provides
for very effective cleaning while at the same time
giving long
fi
lter life.
The dust laden air is introduced into the units cyclone
where most of the dust is separated by the cyclonic
action of the air. This dust falls to the bottom of the
cyclone where it is emptied into a plastic sack. The air
then passes through the
fi
ne
fi
lter and is exhausted
through the pump. HEPA
fi
ltration is available as an
option.
The vacuum is produced by an motor driven turbo-
pump. The turbopump is a regenerative blower where
a direct driven impeller rotates in the pump housing.
The tolerances of the unit are very small so that it is
possible to attain the highest ef
fi
ciency. Because the
pump compresses the air, it is natural that it becomes
hot while running.
Description
Installation
of 4 l/s, 4 bars and a control voltage of 24 V DC,
12 W (which should be taken from the control box).
Connect the tubing system to the inlet and outlet of
the machine. Install and tighten a plastic sack under
the cyclone.
The machine should be equipped with a suitable
electrical starter and installed by a certi
fi
ed electri-
cian. The unit should be equipped with a lockable
disconnect.
Assemble the
fi
lter unit. Mount it on the
fl
oor. Con-
nect the tubing to the inlet and outlet. Connect the
fi
lter cleaning module to a compressed air supply