Part No 94165-D
Service
cyclone (see drawing below) and the
fi
lter can
be removed. When the
fi
lter bottom is over the
edge, you can turn up the bag and tie with wire
ties. Fold the twisted portion again and lock it
with another cable tie. Ideally, no dust release.
Discard the
fi
lter according to regulations. Be
sure to check the
fi
lter seat is clean and the
sealing of the
fi
lter is intact before the
fi
lter is
pressed in and the
fi
lter sits right in the house.
Thereafter, the cyclone top with HEPA
fi
lter
re
fi
tting. Attention! Fine
fi
lter may not be used
long after removal from the machine.
With cleaning and maintenance on the machine,
the power cable should be disconnected from the
supply. Fluids should not come into contact with
the motor.
In every motor unit, the
fi
lter pads (2 pieces, Part
No. 432160) and the air
fi
lter (1 piece, Part No.
432159) must be replaced at least 6 times a year,
and also when cleaning the machine. These
fi
lters
are available as a kit, Part No. 432183. Filter
replacement on the DC 3800 H Asbestos model
requires two packs.