remove it. Once removed slide a bag over the open end of 

the unit (if required) remove the old HEPA filter and replace 

with a new one in the same orientation. Re-clamp on the 

pre-filter and the process is complete. These simple steps are 

outlined below.  

Step 1- Pull filter out after removing the pre-filter 

 

Step 2- Install new filter in same orientation 

 

Changing the pre-filter of the DC AirCube 500 involves sliding 

a bag over the rear of the machine (if required) and 

removing the pre-filter. Removing the pre-filter is done by 

gently pulling the cloth filter from the plastic case. Next Re-

Summary of Contents for DC 2900c

Page 1: ...1 Mobile Instructions This Document is intended to be a condensed version of the DC AirCube 500 manual This is not intended to replace the full manual for the DC AirCube 500...

Page 2: ...r Dustcontrol reserves the right to change speci cations without notice and is under no obligation to alter previously delivered products Dustcontrol is not responsible for errors or omissions in this...

Page 3: ...3 Content Table of Contents Safety Considerations 4 Technical Data 8 Operation 9 Service 9 Accessories 12 Warranty 13 Trouble Shooting 14 Spare Parts 15...

Page 4: ...t particles nor ignition sources are allowed to be sucked into the unit The machine should not be used for explosives unstable or pyrophoric particles or dust WARNING Operators shall be adequately ins...

Page 5: ...can hurt the blood vessels in the skin Don t repair the electric components yourself The machine should be serviced by quali ed personnel only Faults may cause injury See also below under warnings 5...

Page 6: ...Dustcontrol authorized service center If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly quali ed persons in order to avoid a hazard 9 Warning Use onl...

Page 7: ...en should be supervised to ensure that they do not play with the appliance This machine is intended for commercial use only for example in hotels schools hospitals factories shops o ces and rental bus...

Page 8: ...g Pressure Pa inwg 400 1 6 Power Consumption W 145 Degree of Separation EN 60335 2 69 Class H 99 995 Pre Filter cartridge G3 HEPA Degree of Separation EN 1822 1 HEPA H13 99 995 Sound Level Speed 1 Spe...

Page 9: ...o pulse the filter Repeat this 3 6 times Below is a pictorial showing the correct procedure Service During cleaning disconnect unit from power The DC AirCube 500 is equipped with a filter indication l...

Page 10: ...process is complete These simple steps are outlined below Step 1 Pull filter out after removing the pre filter Step 2 Install new filter in same orientation Changing the pre filter of the DC AirCube...

Page 11: ...nes pointing vertically by tucking the edges under the plastic lip of the filter These steps are outlined below Step 1 Remove Dirty Filter Step 2 Reinstall new clean filter Motor Service The fan motor...

Page 12: ...12 Accessories Description Part No Hose 125 mm 2420 Hose clamp 4138 Pre filter 42690 HEPA Microfilter 42692 Funnel 42753 Bracket 42724...

Page 13: ...the condition that the machine is used under normal conditions on the task for which it was designed and is maintained properly Normal wear is not covered by this warranty Service performed by other t...

Page 14: ...your local Dustcontrol dealer Problem Fault Solution Machine blows dust Damaged filter or gasket Change filter Machine runs only on max speed Turning power meter is faulty Change power meter Reduction...

Page 15: ...Spare Parts Below is a simplified parts breakdown of the DC AirCube 500 on the preceding page is a table outlining the parts Contact your local Dustcontrol dealer or full manual for further spare par...