![Dustbane 27100 Parts & Operation Manual Download Page 5](http://html.mh-extra.com/html/dustbane/27100/27100_parts-and-operation-manual_2543182005.webp)
5
Parts & Operations Manual
Fast Track Back Vac
Fast Track Kit Troubleshooting Guide
CAUTION: Always disconnect power cord before servicing.
WARNING: Repairs should only be performed by an authorized service center.
PROBLEM:
Loss of suction
CAUSE
SOLUTION
1. Cap is damaged
1. Inspect and replace if needed
2. Faulty vacuum motor
2. Contact Dustbane or a service center
3. Micro-Ply filter bag is full
3. Replace Micro-Ply filter bag
4. Clogged hose, wand or base cover ports
4. Remove obstruction
5. Loose or broken fan
5. Contact Dustbane or a service center
PROBLEM:
Motor is not running
CAUSE
SOLUTION
1. Faulty ON/OFF switch
1. Contact Dustbane or a service center
2. Power cord defective
2. Contact Dustbane or a service center
3. Loose connection or wiring
3. Contact Dustbane or a service center
4. Motor defective
4. Contact Dustbane or a service center
5. Blown fuse or tripped circuit breaker
5. Replace fuse or reset circuit breaker
PROBLEM:
Dust blowing from vacuum when running
CAUSE
SOLUTION
1. Micro-Ply filter bag is full
1. Replace Micro-Ply filter bag
2. Micro-Ply filter bag not installed properly
2. Reinstall or replace
3. Cloth filter bag dirty
3. Clean cloth filter bag
4. Cloth or Micro-Ply filter bag is torn
4. Replace