17
Operations Manual
Gladiator 1280
The machine won’t start
Battery terminals disconnected.
Check.
Batteries discharged.
Recharge.
Emergency stop button pressed.
Reset.
Driver detection device faulty.
Replace.
Operator not correctly seated.
Sit correctly in the seat.
Main fuse burned out.
Replace.
Power control board fuse burned out.
Replace.
The batteries do not hold their charge
Electrolyte low.
Top up.
Battery terminal loose.
Tighten.
Display Alarms
Alarm
Error indicator
What to do
Brush Motor Cutout Tripped
The brush motor has overheated.
Brake
The parking brake is engaged or the
drive motor has overheated.
Stand-by
The driver detection microswitch is not
detecting an operator.
Release Accelerator
Incorrect starting sequence. Release the
accelerator pedal when starting.
Eeprom 1 Fault
Replace the display board.
Drive Control Board Cutout Tripped
The drive control board has overheated.
Accelerator Fault
There is a problem with the accelerator
cable.
Max. Speed Potentiometer Fault
There is a fault in the maximum speed
potentiometer cabling.
Undervoltage Fault
Check the batteries.
Overvoltage
Check the batteries.
Relay fault
Replace the drive control board.
HPD
Check the accelerator pedal. Switch
the machine off and back on with the
accelerator released.
MOSFET fault
Replace the drive control board.
EEPROM 2 fault
Replace the drive control board.
Service
Call a service centre to arrange servicing.
Battery discharged
Battery discharged.