26
H
0
Warning of excess heat in cooking zone
6. Automatic safety off kitchen feature
When the stove is operating at each capacity level, the stove will automatically
turn off after a certain time corresponding to that power level if there is no
control effect on the stove. This feature is safe if the user is forgotten while the
kitchen is running.
Manual induction hob DLE-888/S
The kitchen's electronic system will automatically stop working and display an
alert if it detects that more than 2 keys hold for more than 10 seconds.
Power level Capacity ratio
Wattage
Operation time (minutes)
Defrost
Heat
1,5%
80
480
3%
1
90
516
7%
2
210
402
12%
3
375
318
21%
4
630
258
30%
5
900
210
41%
6
1250
138
52%
7
1800
138
66,8%
8
2000
108
75,5%
9
2300
90
100%
P
3000
10