10.2 Connections
10.3 Operating conditions
Detail
Value
Maximum allowable mate-
rial temperature when
operating with protective
gloves
40 °C
Maximum allowable mate-
rial temperature when
operating with heat-
resistant protective gloves
60 °C
10.4 Emissions
Work environment sound pressure level
Test: according to EN 14462
Air cap: conventional
Material: Water
Air control: maximum
Air pressure: 2.5 bar
Circular jet
Detail
Value
A-weighted emission
sound pressure level LpA
74 dB(A)
Uncertainty KpA
5 dB
Flat jet
Detail
Value
A-weighted emission
sound pressure level LpA
77 dB(A)
Uncertainty KpA
5 dB
10.5 Operating values
Detail
Value
Max. air pressure
8 bar
Detail
Value
Recommended air pres-
sure
2.0 – 3.0 bar
Air consumption
Example:
Nozzle bore: 1.4 mm
Air control: maximum
Circular jet
Detail
Value
Conventional air cap (CF)
2.5 bar =
10.3 m³/h =
171.0 Nl/min
Air cap LVLP (LF)
2.5 bar =
10.7 m³/h =
178.0 Nl/min
Flat jet
Detail
Value
Conventional air cap (CF)
2.5 bar =
16.7 m³/h =
278.0 Nl/min
Air cap LVLP (LF)
2.5 bar =
18.7 m³/h =
311.0 Nl/min
You can reduce these values via the air flow
control by about 80 % (down to 20 %).
10.6 Type plate
The type plate is placed on the housing and
features the following details:
Product designation
Material number
Year of manufacture
Serial number
EX labeling
Manufacturer
CE labeling
Technical data
05/2018
EcoGun 910 - MSG00003EN
22/32