Changing / Inspecting the Carbon Brushes (Cont.)
Install new brush
Install new carbon brush with bolt.
4.
Connect AVR wires
Insert and connect the 2 wires from the AVR, be sure to connect
+ and – correctly.
5.
6.
Replace generator cover
Replace the back cover of the generator and secure with the
2 bolts.
TROUBLESHOOTING (CONTINUED)