TROUBLESHOOTING
Mode
Description
Solution
Engine will not start
Engine switch is “OFF”
Set engine switch to “ON”
Fuel valve is “OFF”
Turn fuel valve to “ON”
Choke is open
Close the choke
Engine is out of fuel
Add fuel
Fuel is old or contaminated
Change fuel
Spark plug is dirty
Clean spark plug
Spark plug is broken
Replace spark plug
Engine is not level
Move engine to a level
surface
Oil is low
Add/ change oil
Engine starts, but
shuts off after running
for a short time.
Oil level is low
Add change oil
Fuel is old or contaminated
Change fuel
Engine is on incline exceeding
15°
Disconnect low oil sensor