9. Ground
Terminal
3. 120V 3 Prong
Twist Lock
GENERATOR COMPONENTS
12
14. Oil Fill and Dipstick
1.
Propane Connector – Connects the LPG tank to the LPG Regulator.
2.
Engine Switch – 3 Position Switch to “Start”, “Run”, or turn “Off” the generator.
3.
120v 3-Prong Twist Lock - Use to connect electrical devices that run 120 Volt, 60 Hz, single
phase, AC current (L5-30).
4.
Fuel Select Switch - Use to select generator fuel source.
5.
120v 3-Prong Receptacle - Use to connect electrical devices that run 120 Volt, 60 Hz, single
phase, AC current (NEMA 5-20).
6.
Digital Volt Meter/Hour Meter - Provides reading of voltage output and tracks operating
hours.
7.
Circuit Breaker - Resettable switch that protects the generator from electrical overload.
8.
120/240v 4-Prong Receptacle - Use to connect electrical devices that run 120 or 240 Volt, 60Hz,
single phase, AC current (NEMA 14-50).
9.
Ground Terminal - Connect a ground wire here to properly ground the generator.
10.
120/240v 4-Prong Twist Lock - Use to connect electrical devices that run 120 or 240 Volt, 60Hz,
single phase, AC current (NEMA L14-30).
11.
Battery - 12V DC 7ah Battery that powers the Electric Start System.
8. 120/240v
4-Prong Receptacle
7. Circuit Breaker
11. Battery
10. 120/240v
4-Prong Twist
Lock
5. 120v 3-Prong
Receptacle
2. Engine Switch
6. Digital Volt
Meter/ Hour Meter
12. Choke
13. Fuel Valve
Summary of Contents for XP15000E
Page 2: ......
Page 5: ......
Page 26: ...26 ...
Page 32: ...32 ...
Page 35: ...MAINTENANCE LOG Date Generator Hours Maintenance Performed 35 ...
Page 44: ...44 ...
Page 51: ...51 ...
Page 52: ...WIRING DIAGRAM 52 ...
Page 53: ...53 ...
Page 59: ......
Page 60: ...5800 Ontario Mills Parkway Ontario CA 91764 United States 844 DUROMAX ...