-14
PROTECTING THE ENVIRONMENT
Before disposing of damaged, check with your state Environmental
Protection Agency to find out about special restrictions on the disposal of
tool or return them to a certified service center for recycling.
Error Code
Code
Abnormal
Troubleshooting
LV
Battery
Low Voltage
1.
Replace with the other charged battery.
2.
Re-charge the current battery.
OH
Battery
Over Heat
1.
Replace with the other charged battery.
2.
Keep the current battery cool down.
LT
Battery
Low Temp.
1.
Replace with the other charged battery.
2.
Pre-heat the current battery up to 16
℃
OC
Battery
Over Current
Release the trigger then repress the trigger to
restart up
No error code
(Display normal)
In running tool stop
(Motor over heat)
Keep the tool cool down to room temp., press
the trigger to restart up.
No error code
(Display normal)
In running tool stop
(Motor damage)
Keep the tool cool down to room temp., press
the trigger without action.
(Send the tool to service center checking and
repairing by professional technician)
For technical support, call: +
877-693-8665
Service address:
Durofix Inc
.
9168 Pittsburgh Ave.,
Rancho Cucamonga, CA 91766