Adjusting the thread cutter
Service Instructions 969 - 01.0 - 12/2015
77
Setting steps
1. Loosen screws (7) and (8).
2. Move the handwheel to the 80° position (
p. 20).
3. Insert a 0.1 mm feeler gage (2) between the control cam (4) and roller (1).
4. Press the upper lever (3) down and, at the same time,
5. tighten the screw (8).
6. Check the distance between the roller (1) and control cam (4), and adjust
it if necessary.
7. Turn the piston (8) until it is just short of the stop
(distance of approx. 0.5 mm).
8. Tighten the screws (7).
14.3 Adjusting the position of the movable knife
Proper setting
The axis (tip) of the needle (1) is at the left edge of the groove on the
movable knife (2).
If the stop lever (3) is in the park position:
The marking on the movable knife (7) will be covered by the blade of
the fixed knife (8).
Cover
•
•
Feed dog (
p. 16).
•
Tilt the machine head (
p. 10).
Summary of Contents for H-Type 969
Page 1: ...969 Service Instructions...
Page 24: ...Positioning the arm shaft 22 Service Instructions 969 01 0 12 2015...
Page 26: ...Setting the handwheel scale 24 Service Instructions 969 01 0 12 2015...
Page 32: ...Setting the drive 30 Service Instructions 969 01 0 12 2015...
Page 40: ...Setting the stitch length adjusting wheels 38 Service Instructions 969 01 0 12 2015...
Page 48: ...Setting the feed dog 46 Service Instructions 969 01 0 12 2015...
Page 52: ...Aligning the needle bar linkage 50 Service Instructions 969 01 0 12 2015...
Page 60: ...Position of the hook and needle 58 Service Instructions 969 01 0 12 2015...
Page 76: ...Adjusting the thread system 74 Service Instructions 969 01 0 12 2015...
Page 82: ...Adjusting the thread cutter 80 Service Instructions 969 01 0 12 2015...
Page 84: ...Soft start 82 Service Instructions 969 01 0 12 2015...
Page 89: ......