Basic Principles of Working with the Machine
Service Instructions 969 - 01.0 - 12/2015
15
3.3.8 Removing and installing the throat plate
Fig. 8: Removing and installing the throat plate
Removing the throat plate
1. Raise the sewing feet.
2. Loosen the screw (2).
3. Remove the throat plate (1).
WARNING
Risk of injury!
Risk of crushing injuries and stab wounds from
sharp and moving parts.
Switch the machine off before you remove or install
the throat plate.
(1) - Throat plate
(2) - Screws
①
②
Summary of Contents for H-Type 969
Page 1: ...969 Service Instructions...
Page 24: ...Positioning the arm shaft 22 Service Instructions 969 01 0 12 2015...
Page 26: ...Setting the handwheel scale 24 Service Instructions 969 01 0 12 2015...
Page 32: ...Setting the drive 30 Service Instructions 969 01 0 12 2015...
Page 40: ...Setting the stitch length adjusting wheels 38 Service Instructions 969 01 0 12 2015...
Page 48: ...Setting the feed dog 46 Service Instructions 969 01 0 12 2015...
Page 52: ...Aligning the needle bar linkage 50 Service Instructions 969 01 0 12 2015...
Page 60: ...Position of the hook and needle 58 Service Instructions 969 01 0 12 2015...
Page 76: ...Adjusting the thread system 74 Service Instructions 969 01 0 12 2015...
Page 82: ...Adjusting the thread cutter 80 Service Instructions 969 01 0 12 2015...
Page 84: ...Soft start 82 Service Instructions 969 01 0 12 2015...
Page 89: ......