Adjusting the thread cutter
78
Service Instructions 969 - 01.0 - 12/2015
Fig. 54: Adjusting the position of the movable knife
Setting steps
1. Move the handwheel into the 270° position (
p. 20).
2. Swing out the movable knife (2).
3. Loosen screws (5) and (6).
4. Move the knife carrier (3) aside so that the axis (tip) of the needle (1) is
at the left edge of the groove on the movable knife (2).
5. Gently tighten the screw (6) so that the knife carrier (3) can be turned
with a slight frictional torque.
6. Hold screw (5) on the cylinder (4) in the park position and turn the knife
carrier (3) so that the marking on the knife (7) is covered by the blade
of the fixed knife (8).
7. Tighten screws (5) and (6).
14.4 Adjusting the cutting pressure of the knife
Proper setting
While it should be as low as possible, the cutting pressure must allow for
the thread to be cut in a reliable manner.
(1) - Needle axis
(2) - Movable knife
(3) - Knife carrier
(4) - Cylinder
(5) - Screw
(6) - Screw
(7) - Marking on the knife
(8) - Fixed knife blade
①
②
③
⑤
⑥
⑦
④
Summary of Contents for H-Type 969
Page 1: ...969 Service Instructions...
Page 24: ...Positioning the arm shaft 22 Service Instructions 969 01 0 12 2015...
Page 26: ...Setting the handwheel scale 24 Service Instructions 969 01 0 12 2015...
Page 32: ...Setting the drive 30 Service Instructions 969 01 0 12 2015...
Page 40: ...Setting the stitch length adjusting wheels 38 Service Instructions 969 01 0 12 2015...
Page 48: ...Setting the feed dog 46 Service Instructions 969 01 0 12 2015...
Page 52: ...Aligning the needle bar linkage 50 Service Instructions 969 01 0 12 2015...
Page 60: ...Position of the hook and needle 58 Service Instructions 969 01 0 12 2015...
Page 76: ...Adjusting the thread system 74 Service Instructions 969 01 0 12 2015...
Page 82: ...Adjusting the thread cutter 80 Service Instructions 969 01 0 12 2015...
Page 84: ...Soft start 82 Service Instructions 969 01 0 12 2015...
Page 89: ......