background image

en

The mounting instructions come as part of the Duravit 

product and must be read carefully prior to installation.

Target readership and qualifications

The toilet frame may only be installed by a qualified 

plumber. The electrical installation should only be carried 

out by qualified electricians.

Explanation of the key words and symbols

 DANGER

  

Indicates a hazardous situation which, 

if not avoided, will result in death or 

serious injury.

Link to the 

mounting instructions

 in this section

Link to the 

Electrical installation

 section

Link to other 

instructions

Cold water

Water installation

Inspect to check for leaks and leak-tightness

>

Action required

Safety instructions

Risk of fatal electric shock

Contact with electricity can lead to an electric shock.

 

> Carry out the electrical installation in accordance with 

the national, European and international directives and 

standards.

Product and/or property damage

The breach of local and country-specific regulations and 

standards can cause damage to the product 

and/or property damage.

 

> Observe the local installation regulations and any 

country-specific standards at all times.

Prior to the installation

 

> Check the load-bearing capacity of the wall.

 

> Please read the pre-installation data sheets. These are 

available to download on the Internet at  

www.pro.duravit.com.

Mounting instructions

13

 + 

18

Observing the position of the drain

If the height of the toilet frame is set on the 

reference marker, the height of the drain is at 

240 mm.

The height of the toilet frame can be adjusted 

individually: 

 

> Set the height of the toilet frame based on the 

position of the drain according to the technical 

drawing of the toilet.

31

Connecting the toilet frame to the ventilation

 

> Connect the toilet frame according to the 

requirements for ventilation systems.

37

SensoWash

®

 shower toilet (optional)

Duravit recommends carrying out the pre-installation 

when subsequently installing the shower toilet.

38

Installing the water supply for the SensoWash

®

 

shower toilet (optional)

The water supply can be provided via a fixed water 

installation or subsequently via the empty pipe for the 

water installation in the cistern. 

Fixed water installation:

 

> Install the pre-installation set #005072 0000. 

Water connection via the cistern:

 

> Install the connection set #100691 0000.

44

Observing the load-bearing capacity of the wall

 

> Please read the pre-installation data sheets.

6

 MAL_57144/17.05.1

Important information

Summary of Contents for DuraSystem WD1004 000 000

Page 1: ...unting instructions Notice de montage WC Element Geruchsabsaugung Hygienespülung Toilet frame odour extraction hygienic flush Bâti support pour WC système d aspiration d odeurs rinçage hygiénique WD1004 000 000 DuraSystem ...

Page 2: ...2 MAL_57144 17 05 1 ...

Page 3: ...ed nõuanded Elektripaigaldus 26 Ważne informacje Instalacja elektryczna 28 Важные замечания Монтаж электропроводки 30 Důležité pokyny Elektroinstalace 32 Dôležité upozornenia Elektroinštalácia 34 Fontos tudnivalók Elektromos telepítési munkák 36 Važne napomene Elektroinstalacija 38 Indicaţii importante Instalarea electrică 40 Pomembni napotki Električna inštalacija 42 Важни указания Електроинстала...

Page 4: ...n verursachen Installationsvorschriften örtlicher Versorgungs unternehmen sowie länderspezifische Normen uneingeschränkt einhalten Vor der Montage Tragfähigkeit der Wand prüfen Vorinstallationsdatenblätter beachten Diese stehen im Internet unter www pro duravit com zum Download bereit Montagehinweise 13 18 Position des Ablaufs beachten Wenn die Höhe des WC Elements auf den Meterriss eingestellt wi...

Page 5: ...aben des SensoWash Spannungsversorgung erst herstellen wenn das Dusch WC montiert wird 41 Vorinstallation Planung Platzierung für Rohbaudose vorsehen innerhalb 1700mm Grafik A außerhalb der Schutzzonen0 2 Grafik B Dahin festverlegte Zuleitung für Stromversorgung legen separate Absicherung und Fehlerstrom Schutzeinrichtung RCD vorschalten allpolig trennenden Hauptschalter außerhalb der Schutzzonen ...

Page 6: ...s at all times Prior to the installation Check the load bearing capacity of the wall Please read the pre installation data sheets These are available to download on the Internet at www pro duravit com Mounting instructions 13 18 Observing the position of the drain If the height of the toilet frame is set on the reference marker the height of the drain is at 240 mm The height of the toilet frame ca...

Page 7: ...tions for the SensoWash Connect the power supply only when the shower toilet is installed 41 Pre installation planning Plan a position for the concealed box within 1700mm diagram A outside the protection zones0 2 diagram B Install a permanent power supply line there Install a separate circuit breaker and residual current circuit breaker RCCB upstream Connect all pole disconnector mains switches up...

Page 8: ...les normes nationales doivent impérativement être appliquées Avant le montage Vérifier la capacité de charge du mur Tenir compte des fiches de préinstallation Celles ci peuvent être téléchargées sur Internet via le site www pro duravit com Consignes de montage 13 18 Tenir compte de la position de l écoulement Si la hauteur du bâti support pour WC est réglée selon le trait de niveau la hauteur de l...

Page 9: ...sque le WC douche est monté 41 Préinstallation planification Prévoir l emplacement du boîtier de montage brut à l intérieur des 1700 mm graphique A en dehors des zones de protection 0 2 graphique B Y poser un câble fixe pour l alimentation électrique prévoir en amont un fusible dédié et un disjoncteur différentiel séparé RCD prévoir en dehors des zones de protection 0 2 graphique B un interrupteur...

Page 10: ...60 MAL_57144 17 05 1 WD1004 000 000 ...

Page 11: ...1148 240 0 240 1000 0 174 195 MAL_57144 17 05 1 61 WD6008 000 000 ...

Page 12: ...13 mm 4x 2 1 3 1 2 13 mm 62 MAL_57144 17 05 1 7 6 5 4 2 1 3 8 14 15 22 ...

Page 13: ...UW 50 UW 75 UW 75 2x 8x70 2x 8 4 2x MZ10 Ø 10 mm MAL_57144 17 05 1 63 11 10 9 8 12 ...

Page 14: ...13 mm 2x 8 6x23 5x1 8 2x 8x20 1 2 8x 4 8x16 1 2 2 13 mm 100 2 1 3 0 240 240 1000 64 MAL_57144 17 05 1 17 WD6008 000 000 16 15 14 13 23 ...

Page 15: ...13 mm 2 1 3 100 0 240 240 1000 1 3 2 13 mm 1 2 4x MZ10 Ø 10 mm 13 mm 4x 8x70 4x 8 4 MAL_57144 17 05 1 65 22 21 20 19 18 ...

Page 16: ...19 mm 1 2 1 2 1 2 29 30 31 66 MAL_57144 17 05 1 29 28 26 25 24 23 27 ...

Page 17: ... 1 100 1 2 1 MPa 10 bar 145 PSI 32 MAL_57144 17 05 1 67 33 31 32 30 36 34 35 ...

Page 18: ...0 0 1700 0 1700 SensoWash 800 68 MAL_57144 17 05 1 41 38 37 39 38 40 39 ...

Page 19: ...4x 4x12 68 12 5 12 5 MAL_57144 17 05 1 69 46 45 X 44 43 42 47 ...

Page 20: ...1 1 2 2 1 3 70 MAL_57144 17 05 1 X 53 52 51 50 48 49 ...

Page 21: ...200 1 2 2 MAL_57144 17 05 1 71 59 55 54 56 58 57 ...

Page 22: ...N L N L 1 2 72 MAL_57144 17 05 1 65 63 61 60 62 64 66 ...

Page 23: ......

Page 24: ......

Page 25: ......

Page 26: ...We reserve the right to make technical improvments and design modifications to the products illustrated DURAVIT AG P O Box 240 Werderstr 36 78132 Hornberg Germany Phone 49 78 33 70 0 Fax 49 78 33 70 289 info duravit com www duravit com ...

Reviews: