600
600
2250
2
1
0
The electrical installation should only be
carried out by qualified electricians.
Explanation of the key words and symbols
DANGER
Indicates a hazardous situation
which will result in death or serious
injury if not avoided.
Technical data
Rated voltage
100 – 240 V
Frequency
50/60 Hz
Power consumption in standby < 0.5 W
Max. power consumption
15 W
Protection class
IP X4
Circuit breaker
I
N
= 16 A
Residual current circuit
breaker RCD
I
∆N
≤ 30 mA
Safety instructions for the electrical
installation
DANGER
Risk of fatal electric shock
> Carry out the electrical installation in
accordance with the national, European
and international directives and standards.
> Switch off the power supply before the
installation.
> Prevent the power supply from being
switched on accidentally. Prevent recon-
nection according to DIN VDE 0105-100.
> Connect the circuit breaker and residual
current circuit breaker (RCD) that
disconnects all phases from the mains.
> If the power supply cable of this unit is
damaged, the power supply cable must
be replaced by the manufacturer, their
Customer Services or a similarly qualified
person.
> Observe the protection zones.
> Do not install the power supply in
protection area 0 or 1.
> Place the socket outside the protection
areas.
> If necessary, install the tap unit in
protection area 2.
Safety areas in accordance with
DIN VDE 0100-701
MAL_57325/20.07.3
7
en
Summary of Contents for D.1e
Page 2: ......
Page 60: ... D11100 0070 D11110 0070 60 MAL_57325 20 07 3 ...
Page 61: ...7 Nm 1 2 1 2 3 4 5 6 D11110 0070 MAL_57325 20 07 3 61 ...
Page 62: ...70 7 8 9 10 11 12 62 MAL_57325 20 07 3 ...
Page 63: ...99 56 Ø 5 mm 2x 3 5x40 1 2 3 4 5 6 13 14 15 16 17 18 MAL_57325 20 07 3 63 ...
Page 64: ...8 Nm 19 mm 19 mm 20 mm 1 2 3 4 5 6 19 20 21 22 23 24 64 MAL_57325 20 07 3 ...
Page 65: ...00 02 00 25 26 27 MAL_57325 20 07 3 65 ...
Page 66: ...12V 66 MAL_57325 20 07 3 ...
Page 67: ... 6 8 7 9 10 11 12 MAL_57325 20 07 3 67 ...
Page 68: ...1 2 3 68 MAL_57325 20 07 3 ...
Page 69: ...microfibre 15 25 C 1 2 3 4 1 2 3 4 MAL_57325 20 07 3 69 ...
Page 70: ......
Page 71: ......