background image

 

 

FOUNDATION

 

GUARDIAN WOODEN FLOOR 

 

 

• 

The optional Guardian kitset wooden floor is precut and designed 
to be fitted into the shed after the shed is assembled.

 

 

 

• 

Assemble shed as per  instructions and fit floor last.

 

          (see page 13 for details). 

 

CONCRETE SLAB FOR RAISED BASE PLATE SHED

 

 

To build a raised concrete slab for your shed to sit on, we recom-

mend the following:

 

 

• 

The raised slab size should be 15mm smaller than the base 
size of the shed and at least 30mm above ground line.

 

 

• 

The slab should be 80mm thick in the middle and 100mm 
thick around the edges.

 

 

• 

The slab should be laid on a solid or compacted base.

 

 

• 

Plastic sheeting under slab will prevent moisture coming 
through from underneath

.

 

 

• 

During construction, you may raise the  bottom timber 
plate to allow the wall cladding to protrude 20mm below 
the bottom plate. This will stop water flowing between 
the bottom plate and the concrete floor. 

 

          

See note on page 8.

 

80mm

 

100mm

 

7.5mm

 

20mm

 

Concrete Floor

 

Base Plate

 

Wall Cladding

 

6

 

RAISED BASE PLATE OPTION

 

(For sheds placed on a raised concrete floor)

 

No doubt by now you will have decided what sort of base you are putting down. 

 

Please read the section that applies to your situation.

 

If you choose to pour a concrete base you will need to decide whether you wish to raise the base plate of your shed. 

This allows the cladding to protrude below the surface of the concrete and ensures a water tight pad. 

 

See concrete pad specifications below

 

By choosing this option you will need to make the concrete pad to the specification below.

 

Summary of Contents for Guardian Sheds GS73

Page 1: ...ASSEMBLY INSTRUCTIONS GS73 BASE SIZE 2 190m x 1 020m...

Page 2: ......

Page 3: ...ocess needs to be adhered to to qualify for the steel warranty of your Duratuf Guardian shed Wash all surfaces annually using a hose and soft nylon brush Within 2 km of coast wash every 3 months as ab...

Page 4: ...90m 1 Front Wall 1 890m 2 Back Wall 1 950m 4 Back Wall 1 Pan 1 950m 1 Side Wall Angle 1 905m 2 Side Wall Angle 1 935m 2 Roof 1 110m 4 Roof 1 Pan 1 110m 1 Door Sheet Narrow 1 850m 2 Door Sides 1 850m 2...

Page 5: ...RIPTION QTY DIAGRAM CHECKED Front Back Bottom Plates H4 Green 2 190 m 2 Front Back Top Plate H1 Red 2 190 m 2 Side Wall Bottom Plates H4 Green 1 020 m 2 Side Wall Top Plates H1 Red 1 022m 2 Spouting 2...

Page 6: ...ASSEMBLE BACK PANEL Top Plate Back Side Wall Sheets Barge Flashing Spouting Roof Sheets 4 Sheets 1Pan Sheet Top Plate Side Top Plate Front Bottom Plate Front Bottom Plate Side Back Wall Sheets 4 Shee...

Page 7: ...hrough from underneath During construction you may raise the bottom timber plate to allow the wall cladding to protrude 20mm below the bottom plate This will stop water flowing between the bottom plat...

Page 8: ...door as shown ensuring narrow face of flashing is on the front as per fig 1 STEP 4 On the back of the door place door braces in posi tion as shown in fig 4 Ensure that the top and bottom ends of the b...

Page 9: ...Rivet sheets together on overlaps as shown STEP 3 Nail wall sheets to the Top Plate at each end making sure that the top of the sheets are flush with the top of the Top Plate and the sides of the wal...

Page 10: ...er on overlaps as shown BOTTOM PLATE TOP PLATE TOP PLATE 15mm 15mm BOTTOM PLATE 15mm 15mm 1918mm 1918mm TOP PLATE STEP 3 Nail the wall sheets to the Top Plate at each end making sure that the top of t...

Page 11: ...MBER BASE PLATE READ THE FOLLOWING For sheds with Raised Base Plate option only see page 6 deduct 30mm from measurement shown between Top and Bottom Plates on all wall panels so cladding protrudes 20m...

Page 12: ...h the second Side Panel ensuring that the Side Panel overlaps the Back Wall Panel STEP 3 Stand up the Front Wall Panel Ensure that the Front Wall Sheets overlap the Side Wall Sheets Using 8 x 40mm scr...

Page 13: ...ing up with the outside edge of the back wall cladding as in fig 4 Using 4 x 50mm Clouts predrill and nail the Roof Sheets to the Top Plates through the ribs at each corner ensuring ribs on the Roof S...

Page 14: ...onry drill bit is required FITTING A GUARDIAN FLOOR KIT OPTIONAL Position the Floor Joists centrally between the side Base Plates and skew nail each end with two 75mm nails Check that the shed is sitt...

Page 15: ......

Page 16: ...less than 200g m2 as published by Branz Warranty certificate being returned to manufacturer within 21 days of purchase together with proof of purchase This warranty does not cover the following Faste...

Reviews: