Duratool D03405 Manual Download Page 7

Beaufort scale 

m/s 

kts 

mph 

km/h 

ft/min 

0-0.2

0-1

0-1

0-1

0-58

0.3-1.5 

1-3

1-3

1-5

59-314

1.6-3.3 

4-6

4-7

6-11

315-668

3.4-5.4 

7-10

8-12

12-19

669-1082

5.5-7.9 

11-16

13-18

20-28

1083-1574 

8.0-10.7 

17-21

19-24

29-38

1575-2125 

10.8-13.8 

22-27

25-31

39-49

2126-2735 

13.9-17.1 

28-33

32-38

50-61

2736-3385 

17.2-20.7 

34-40

39-46

62-74

3386-4093 

20.8-24.4 

41-47

47-54

75-88

4094-4822 

10 

24.5-28.4 

48-55

55-63

89-102

4823-5609 

11 

28.5-32.6 

56-63

64-72

103-117

5610-6417 

12 

>63

>72

>117

>6417

9.2 Low battery display 

The unit will detect the voltage of battery just after power on. In

 

normal 

mode,  the  unit  detects  low  battery  every  10  minute.  In  power  off 
mode do not detect it, if the battery  voltage is  low, the icon 

 

  will 

be displayed.  

9.3 Power ON/OFF 

Press and hold down the “

SET

” key for 4 seconds to switch the unit 

ON or OFF. In power off mode the unit will sleep and do not detect 
the  wind  speed  and  temperature  data,  all  the  history  data  will  be 
cleared too. 

In Wind speed mode, the meter will automatically switch OFF when no key is pressed and the wind 
speed is zero for 30 minutes to save battery life. 
In Altitude display mode, the meter will automatically switch OFF when no key is pressed for 24hours 
to save battery life. 

10. Glossary of Terms

Term 

Definition 

Accuracy 

Accuracy is defined as the ability of a measurement to match the 
actual value of the quantity being measured. 

Beaufort Scale 

The  Beaufort  Scale  is  an  empirical  measure  for  describing  wind 
speed  based  mainly  on  observed  sea  conditions  (on  land  it  is 
categorized  by  the  physical  effects  it  has  on  vegetation  and 
structures). Its full name is the Beaufort Wind Force Scale. 

>

32.6

Summary of Contents for D03405

Page 1: ...Handheld Anemometer Model D03405 hold set...

Page 2: ...or Knots 2 Wind speed in Beaufort wind scale bar graph 3 Wind chill display 4 Temperature display in degrees Fahrenheit or Celsius 5 Barometric display in hPa inHg mmHg 6 ABS REL MAX altitude display...

Page 3: ...splay current WIND default maximum WIND Average WIND In wind speed mode hold this key for 2 seconds current Max Average wind speeds will be cleared In the Altitude mode press it to change the display...

Page 4: ...nd speed will show 0m s and if the speed over 30m s the wind speed will show Note 1 It will stop measuring wind speed once exit wind speed mode 2 If no wind speed or no button operation within 30 minu...

Page 5: ...altitude display modes Relative Altitude Maximum Altitude Absolute Altitude Press the key to toggle among the three altitude display modes Relative Altitude Maximum Relative Altitude Absolute Altitude...

Page 6: ...ashing Press key to cycle between C and F Press SET key to confirm and advance to the next step 3 The barometric unit will begin flashing Press key to cycle among hPa inHg mmHg Press SET key to confir...

Page 7: ...ll be displayed 9 3 Power ON OFF Press and hold down the SET key for 4 seconds to switch the unit ON or OFF In power off mode the unit will sleep and do not detect the wind speed and temperature data...

Page 8: ...above 50 F and is not displayed out of range or Impeller appears imbalanced It is normal for the impeller to oscillate as it comes to a stop and it is not imbalanced The unit contains a very small ma...