background image

7

OPERATION - DC CURRENT MEASUREMENT

• 

Connect the red test lead to the “VΩmA” jack and the black test lead to the “COM” 

jack. 

• 

Note: for measurements between 200mA and 10A, remove the red lead to the 

“10A” jack.

• 

Set the rotary switch at the desired DCA position.

• 

Open the circuit in which the current is to be measured and connect the test leads 

in series with the circuit.

• 

Read the current value on the LCD along with the polarity of th red lead 

connection.

OPERATION - AC VOLTAGE MEASUREMENT

• 

Connect the red test lead to the “VΩmA” jack and the black test lead to the “COM” 

jack.

• 

Set the rotary switch at the desired ACV position.

• 

Connect test leads across the source or load being measured.

• 

Read the voltage on the LCD.

OPERATION - RESISTANCE MEASUREMENT

• 

Connect the red test lead to the “VΩmA” jack and the black test lead to the “COM” 

jack. 

• 

Note: the polarity of the red lead is positive.

• 

Set the rotary switch at the desired “Ω” range position.

• 

Connect the test leads across the resistor to be measured and read the LCD.

• 

If the resistance being measured is connected to a circuit, turn off the power and 

discharge all capacitors before applying test probes.

OPERATION - DIODE TEST

• 

Connect the red test lead to the “VΩmA” jack and the black test lead to the “COM” 

jack. 

• 

Note: the polarity of the red lead is positive.

• 

Set the rotary switch at the “         ” position.

• 

Connect the red test lead to the anode of the diode to be tested and the black test 

lead to the cathode of the diode.

• 

The approximate forward voltage drop of the diode will be displayed. If the 

connection is reversed, only figure “1” will be shown.

OPERATION - TRANSISTOR TEST

• 

Set the rotary switch at the “hFE” position.

• 

Determine whether the transistor under testing is NPN or PNP and locate the 

emitter, base and collector leads. Insert the leads into the proper holes of the hFE 

socket on the front panel.

• 

Read the approximate hFE value and the test condition of the base current 10µA 

and Vce 3V.

Summary of Contents for D03126

Page 1: ...1 MODEL D03126 Digital Multimeter with Backlight...

Page 2: ...ge 5 DC Current 6 AC Voltage 6 Diode Continuity 6 Resistance 6 Transistor hFE Test 0 1000 6 Operation DC Voltage Measurement 7 Operation DC Current Measurement 7 Operation AC Current Measurement 7 Ope...

Page 3: ...s from the circuit under test When measuring a TV set or switching power supply watch out for pulses in the circuit that may damage the meter Before working with and measuring voltages higher than 60V...

Page 4: ...ed to select functions and desired ranges as well as turn the meter on or off 4 V mA jack plug in the connector for red positive test lead for voltage resistance and current except 10A measurements 5...

Page 5: ...38mm x 69mm x 31mm Weight Approx 170g Accuracy is specified for a period of one year after calibration and at 18 to 28 C 64 F to 82 F with relative humidity to 80 DC VOLTAGE Range Resolution Accuracy...

Page 6: ...8 of rdg 2 digits 200k 100 0 8 of rdg 2 digits 2M 1k 1 0 of rdg 2 digits Maximum open circuit voltage 3 2V Overload protection 250V DC or RMS AC for all ranges TRANSISTOR hFE TEST 0 1000 Range Test Ra...

Page 7: ...s positive Set the rotary switch at the desired range position Connect the test leads across the resistor to be measured and read the LCD If the resistance being measured is connected to a circuit tur...

Page 8: ...cation Be careful to observe the battery polarity Never use the meter unless the back cover is in place and securely fastened CLEANING Use a soft clean dry cloth to clean the meter Do not use any chem...

Reviews: