background image

3

IMPORTANT SAFETY INFORMATION
Please read these instructions carefully before use and retain for future 

reference.

Important safety information. Read the instructions carefully.
High voltage. Danger.
Ground.
Double Insulation (Class II safety equipment).

Fuse must be replaced as per the specification herein.

!

200mA/250V

• 

When using electrical appliances basic safety precautions should always be 

followed.

• 

Do not exceed the protection limit values specified for each range range of 

measurement.

• 

Never use the meter to measure voltages that might exceed 600V above earth 

ground in category II installations.

• 

When the value scale to be measured is unknown beforehand, set the range 

selector to the highest position.

• 

Before rotating the range selector to change the functions disconnect the test 

leads from the circuit under test.

• 

When measuring a TV set or switching power supply, watch out for pulses in the 

circuit that may damage the meter.

• 

Before working with and measuring voltages higher than 60V DC or 30V AC RMS, 

keep your fingers behind the probe barriers.

• 

Before attempting to insert transistors for testing, always be sure that the test 

leads have been disconnected from any measurement circuits.

• 

Components should not be connected to the hFE socket when making voltage 

measurements with test leads.

• 

Do not perform resistance measurements on live circuits.

• 

The instrument can only be used in conjunction with the test leads supplied. If 

necessary, they must be replaced with the same type and specification.

WHAT’S INCLUDED?

• 

One instruction manual

• 

One digital multimeter

• 

Set of test leads

• 

One 9V battery, NEDA 1604 6F22 006P type

• 

Holster (optional)

This meter is a handheld 3½ digital multimeter used for measuring DC and AC voltage, 

DC current, resistsance, diode, transistor and continuity.

Summary of Contents for D03126

Page 1: ...1 MODEL D03126 Digital Multimeter with Backlight...

Page 2: ...ge 5 DC Current 6 AC Voltage 6 Diode Continuity 6 Resistance 6 Transistor hFE Test 0 1000 6 Operation DC Voltage Measurement 7 Operation DC Current Measurement 7 Operation AC Current Measurement 7 Ope...

Page 3: ...s from the circuit under test When measuring a TV set or switching power supply watch out for pulses in the circuit that may damage the meter Before working with and measuring voltages higher than 60V...

Page 4: ...ed to select functions and desired ranges as well as turn the meter on or off 4 V mA jack plug in the connector for red positive test lead for voltage resistance and current except 10A measurements 5...

Page 5: ...38mm x 69mm x 31mm Weight Approx 170g Accuracy is specified for a period of one year after calibration and at 18 to 28 C 64 F to 82 F with relative humidity to 80 DC VOLTAGE Range Resolution Accuracy...

Page 6: ...8 of rdg 2 digits 200k 100 0 8 of rdg 2 digits 2M 1k 1 0 of rdg 2 digits Maximum open circuit voltage 3 2V Overload protection 250V DC or RMS AC for all ranges TRANSISTOR hFE TEST 0 1000 Range Test Ra...

Page 7: ...s positive Set the rotary switch at the desired range position Connect the test leads across the resistor to be measured and read the LCD If the resistance being measured is connected to a circuit tur...

Page 8: ...cation Be careful to observe the battery polarity Never use the meter unless the back cover is in place and securely fastened CLEANING Use a soft clean dry cloth to clean the meter Do not use any chem...

Reviews: