Although the heat pump is electrically isolated from the rest of the pool equipment, this only prevents the 
passage of electricity to or from the pool water. Grounding the unit is still required to protect yourself from 
short circuits inside the unit. Provide an adequate ground connection.

OUT - Water connection from heat pump: 

Typical water pipe from heat pump to water treatment system.

IN - Water connection to heat pump: 

Typical water pipe from filter system to heat pump.

You should always switch off the heat pump immediately when the RCD indicator is turned “OFF”.

Be extremely careful when pressing “RESET” after a failure because there might still be a problem.

The  controller  of  the  Sun  Spring  heat  pump 

has a memory so that the settings are retained 

even if the power is switched off and on. This 

makes it possible to operate the heat pump with 

a timer. The timer must be installed between the 

heat pump and the RCD plug, see picture. The 

installation  must  be  carried  out  by  a  certified 

electrical installer in order to guarantee quality 

and safe operation.

Test the RCD before usage as follows:

1. Plug the RCD into a fixed socket
2. Press the “RESET” button.  The indicator should be “ON”.
3. Press the “TEST” button.  The indicator should be “OFF”.
4. Press the “RESET” button again to start using the heat pump

4.4 Electrical wiring

4.3 Installation of the tubing

The heat pump should be located 2m (recommended) away from the swimming pool. The longer 

the distance from the pool, the greater the heat loss from the piping. The piping to and from the heat 

pump need to fit the chosen connections. The pipes can be glued, clamed or screwed onto these 

water connections and can be made out off hard or flexible PVC. Always install piping intended for 

swimming pool use and use the correct glue to put them together.

Always check if the voltage from the network corresponds with the operating voltage of the unit. 

Your  typical  swimming  pool  configuration  can  be  controlled  using  a  timer.  Please  contact  your 

service centre or similarly qualified persons to change the RCD into a standard electrical plug. A 

timer can be put in between the heat pump AND pool circulation pump once a standard electrical 

plug is installed. Using a timer; The heat pump and pool circulation pump will start up automatically 

as soon as power is broken and restored. The heat pump remembers its last status and starts up 

with last remembered settings.

Summary of Contents for Sun Spring

Page 1: ...Manual SUN05 SUN08 SUN12 Sun Spring...

Page 2: ...d use 6 1 Before operation 6 2 Initial startup 6 3 General interface 6 4 Parameter interface 6 5 Parameter list 6 6 Error interface 6 7 Error parameter interface 6 8 Error list 6 9 Trouble shooting gu...

Page 3: ...3 ENG Box content Manual Heat pump Sun Spring Connection kit 456mm 87mm 87mm 456mm 467mm 467mm 530mm 750mm 90mm 90mm SUN05 SUN08 SUN12 Dimensions x2...

Page 4: ...ontroller Colour LCD Nominal Running current A 3 1 5 1 Max Current A 5 7 RCD Rated current A 10 EU UK SWISS 10 EU UK SWISS RCD Leakage current mA 30 Condensor Titanium Heat Exchanger NoFrost Compresso...

Page 5: ...30V 50Hz 1 Phase Electronic Controller Colour LCD Nominal Running current A 9 Max Current A 12 RCD Rated current A 16 EU SWISS 13 UK RCD Leakage current mA 30 Condensor Titanium Heat Exchanger NoFrost...

Page 6: ...in order to avoid a hazard 10 Always make sure the water connections of the heat pump are properly locked before you start using the machine 11 Never insert objects directly into the fan as this will...

Page 7: ...2 Put the heat pump on a flat solid base Tilting the heat pump for max 3 is allowed Install silent blocks in order to avoid vibrations and noise All feeding of water treatment to the pool water has t...

Page 8: ...ns for connecting the water pipes as shown below 1 1 1 1 1 2 2 2 2 3 4 5 6 3 4 2 5 6 1 Custom thread to connect part 2 2 Custom thread to connect part 1 BSP G1 1 2 straight external pipe thread 3 Hose...

Page 9: ...ug the RCD into a fixed socket 2 Press the RESET button The indicator should be ON 3 Press the TEST button The indicator should be OFF 4 Press the RESET button again to start using the heat pump 4 4 E...

Page 10: ...at the water is condensation is to shut off the unit and keep the pool pump running If the water stops running out of the base pan it is condensation AN EVEN QUICKER WAY IS TO TEST THE DRAIN WATER FOR...

Page 11: ...ter the parameter menu by pushing the up and down button simultaneously 2 Go to the fahrenheit parameter P02 by pressing up down buttons 3 Press the on off button to enter the parameter set mode 4 Adj...

Page 12: ...o stop the heat pump OFF will appear on the display UP Press to increase desired temperature Any changes will be saved automatically Down Press to reduce desired temperature Any changes will we be sav...

Page 13: ...when you scroll through the list of parameters When the ON OFF has been pushed it will be visible and the selected parameter can be changed Up Scroll up through the list of parameters Edit the value...

Page 14: ...2 5 PPS PASSWORD P8 10 0 PPS PASSWORD P9 0 5 PPS PASSWORD P10 10 0 PPS PASSWORD P11 5 0 PPS PASSWORD TA Ambient temperature Value of the ambient temperature TIN Water in temperature Value of the water...

Page 15: ...sensor error Liquid line temperature sensor error Water inlet temperature sensor error By pressing UP DOWN simultaneously the Error parameter interface we ll be entered Here it is shown which specifi...

Page 16: ...e RCD If the pump still shows the error after that please contact your service centre or similarly qualified person Condensor water inlet temperature error The water inlet temperature sensor is broken...

Page 17: ...professional pool or air conditioning contractor Read the entire installation and users guide before attempting to use service or adjust the heater or pool filtering system Do not start the heat pump...

Page 18: ...rface diagram Sun Spring FUSE RY1 RY2 TRANSFORMER Y G Y G RED BLU BLK BLU C C L N RED ORG BLK WHI S COMP FAN R C DISPLAY 230VAC POWER SUPPLY Te Evap Temp sensor Tc Cond Temp sensor Tin Water In Temp s...

Page 19: ...19 ENG 7 2 Piping diagram and definition Sun Spring Condensor Strainer Capillary Evaporator Compressor Win Tamb Tliq Tevap...

Page 20: ...s been stored for a long time perform the following steps when re starting the system 1 Inspect the system for any debris or damage to the case 2 Clean the evaporator fins with a soft cloth if necessa...

Page 21: ...central point for recycling of electrical and electronic domestic applications By doing this you will help to preserve the environment 11 Service If you need service or information or if you have a p...

Page 22: ...ater flow rates outside the published minimum and maximum specifications 7 Use of non factory authorized parts or accessories in conjunction with the product 8 Chemical contamination of combustion air...

Page 23: ...23 ENG...

Page 24: ...stems bvba Dooren 72 1785 Merchtem Belgium Tel 32 2 461 02 53 Fax 32 2 706 59 60 www duratech be info propulsionsystems be We reserve the rights to change all or part of the contents of this document...

Reviews: