4.1 Typical set-up
The factory provides the heat pump and connection kit. Other parts, including a contingent by-pass must be
provided by the user or installer. The heat pump should be located 2m (recommended) away from the swimming
pool. The longer the distance from the pool, the greater the heat loss from the piping.
4. Preparing the heat pump for use
Valve
Water supply
Water outlet
Outlet valve
Inlet valve
Bypass valve (recommended)
Filter
Water inlet
Water pump
Swimming Pool
Water treatment(2)
Put the heat pump on a flat, solid base. Tilting the heat pump for max 3° is allowed.
Install silent blocks in order to avoid vibrations and noise.
All feeding of water treatment to the pool water has to be done downstream of the heat pump(2).
It is normal for condens water to come out of the heat pump. This is not a leak or fault with the unit. If the
humidity is very high, the condens water could be a number of liters a day. Please find more information
about condensation in section 5.2.
Always keep the heat pump in upright position. If the unit has been tilted, then wait 24h before starting the
heat pump.
Heat pump
2 Meter (recommended)
It is recommended to install a by-pass for easy maintenance.