1. PRESENTATION  

STANDGAS HC & HC PRO

 are stand-alone detectors for explosive gases using catalytic technology (pellistor) for a detection 

range from 0 to 100% LEL. Silicon vapours resistant sensors (HDMS) 

  Available formats and gases

    

 

STANDGAS HC    

 

 

   

 

Available for natural gas-methane, butane-propane, and hydrogen.

  STANDGAS HC PRO

Available for natural gas-methane, hydrogen, butane, propane, heptane, hexane, pentane, methanol,styrene, 

ethane, ethanol, ethylene, propylene, acetone, ammonia, acetylene,  cyclo-hexane, cyclo-pentane, 

dioxane, butyl acetate, ethyl acetate,acetic acid, iso-butyl alcohol, iso-propyl alcohol, decane, benzene, 

octane, methyl ethyl ketone, nonane, propanol, toluene, xylene. Other gases, consult.

  Other features

• Optical indications for sensor fault. 

• 

Programmable alarm relay.

• 

Selection of gas to detec using a jumper.

• 

Silicon vapours resistant sensors (HDMS). 

Do not use these detectors in environments where there might be presence of hydrogen sulphide, fluorine, methyl chloride, 

trichloroethylene, sulphur dioxide, silicon vapours or sulphuric acid: the presence of these gases could either inhibit 

sensor’s response or damage it.

 

Summary of Contents for STANDGAS HC

Page 1: ...STANDGAS HC HC PRO STAND ALONE DETECTORS FOR EXPLOSIVE GASES Installation User Manual 2011 DURAN ELECTRONICA S L All rights reserved www duranelectronica com I manSTANDGASexp v02 Certificate n FS82426...

Page 2: ......

Page 3: ...PRESENTATION 5 2 RELAY MODULE 6 3 CONNECTIONS 6 4 PROGRAMMING AND GAS GROUP SELECTION 7 5 EXTERNAL OPTICAL INDICATIONS messages functioning 9 6 TEST RECALIBRATION 9 7 TECHNICAL CHARACTERISTICS 10 8 G...

Page 4: ...4 2011 DURAN ELECTRONICA S L All rights reserved www duranelectronica com...

Page 5: ...ylene acetone ammonia acetylene cyclo hexane cyclo pentane dioxane butyl acetate ethyl acetate acetic acid iso butyl alcohol iso propyl alcohol decane benzene octane methyl ethyl ketone nonane propano...

Page 6: ...lay disconnection retard It allows to select a retard or the instantaneous disconnection since the level selected has disappeared as an alarm condition It has no effect if INSTANTANEOUS was previously...

Page 7: ...ule with the detector powered Watch carefully the external LED blinking see table 1 below When the number of LED blinking fits in with the gas group to be detected place JP3 jumper again and watch tha...

Page 8: ...ane 30 cm from floor 6 Dioxane 30 cm from floor 6 Ethyl Acetate 30 cm from floor 6 Iso Propyl Alcohol IPA 30 cm from floor 6 Methyl Ethyl Ketone MEK 30 cm from floor 6 Butane 30 cm from floor 6 Hexane...

Page 9: ...the detector In case this condition is not fulfilled the detector must be subjected to a concentration of pure nitrogen with a 0 5l min flow for 2 minutes minimum using the optional CECALIBR adaptor...

Page 10: ...DC 2 wires Max consumption 130mA to 12V DC with relay activated 110mA to 12V DC with relay activated Loop max resistance 250 250 Max current output 21 3 mA Tip 21 3 mA Tip Fault loop current 2mA 2mA E...

Page 11: ...11 I manSTANDGASexp v02...

Page 12: ...c Tom s Bret n 50 28045 MADRID Espa a Tel 34 91 528 93 75 Fax 34 91 527 58 19 duran duranelectronica com www duranelectronica com I manSTANDGASexp v02 Certificado n FS82426...

Reviews: