NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
10
4
. Remove the screw on the wind
cover and remove the wind cover.
6
. Unscrew & remove 4 wing nuts.
5
. Remove the screw on the safety
shut off assembly and remove
the safety shut off assembly.
10
. The black line on the outside of
the wick should match the top
edge of the holder.
Then press it against the teeth
inside the holder to obtain a
firm grip.
12
. Insert the pinion at the other
end of the wick control shaft
into the top portion of the rack
of the wick holder.
This step can be easily carried
out if the wick holder is raised.
11
. Replacement the wick holder
assembly in the burner tank.
Rotate 90 degrees left and
right as well as up and down
until the wick slides freely.
Check to see that gasket is
still in place on the burner
tank.
7
. Lift the wick adjuster assembly
straight up and away from the
heater.
9
. Remove the wick from the
holder by folding it toward the
center loosening it from the
sharp metal teeth on the inner
surface of the inner surface of
the holder, and slide it out.
8
. Lift the wick holder assembly
straight up and remove form the
burner tank.