Duraflame DFI-5020-01 Manual Download Page 8

www.tsicustomerservice.com

A606

8

TROUBLESHOOTING GUIDE

Problem

Root Cause

Corrective Action

10. Not producing
  enough heat.

10a. power strip/surge protector/
 

extension cord being used

10b. Location of unit.

10a. Plug unit directly into the wall.
10b. Make sure unit is located on an interior wall.

11. Unit blows cool or
  cold air.

11.  Defective heater blower 
         assembly.

11.  Replace heater blower assembly.

12. Noise with
  heater on.

12a. Dirty heater blower motor
12b. Defectiveheater/blower 
         assembly.

12a. Gently vacuum heater blower vents.
12b. Replace heater/blower assembly.

13. Noise with flames
  on and heater off.

13a. Defective flame generator
 

drive motor.

13b. Dented back panel
13c. Warped spinner shaft

13a. Replace flame generator drive motor.
13b. Refer to TSI customer service.
13c. Refer to TSI customer service.

14. Is it safe to place
  unit on carpet?

14.   Product Inquriy

14.  It is safe to place unit on carpet but make sure any flammable
 

items are at least 3 feet away from front and sides of the unit.  

15. How many square
  feet will my unit
  warm up?

15.    Product Inquriy

15.  Provides supplemental heat up to 1000 square feet

16. Flame effect works
       but heater 
       function does not
       and the ember bed
       flashes when
       the heater button
       is pressed.

16.   The heater is disabled.

16.  With the power on press and hold the POWER button on the
        control panel for 10 seconds. Once re-enabled the emberbed
        lights will flash multiple times.

17. Remote control is
      not working when
      buttons are 
      pressed.

17a. No batteries or battery power. 
17b. Poor signal
17c. Distance

17a. Change the remote batteries.
17b. Operate remote transmitter at a slow measured pace. Press the 
         remote control buttons with an even motion and gentle pressure.
         Repeatedly pressing buttons in rapid succession may cause the
          transmitter to malfunction.
17c. Operate the remote at a distance less than 20 feet from the front
         of the appliance; point the remote at the control panel.

Summary of Contents for DFI-5020-01

Page 1: ...tsicustomerservice com 1 888 674 7517 www tsicustomerservice com A606 1 Twin Star International Inc Delray Beach FL 33445 Made in China MODEL DFI 5020 01 DFI 5020 02 DFI 5020 03 DFI 5020 04 DFI 5020...

Page 2: ...ater may include a visual alarm to warn that parts of the heater are getting excessively hot If the alarm flashes immediately turn the heater off and inspect for any objects on or adjacent to the heat...

Page 3: ...CT SPECIFICATIONS VOLTAGE 120VAC 60 Hz AMPS 12 5 Amps WATTS max 1500 Watts 1 888 674 7517 www tsicustomerservice com SN AB XXXXX X Date Code Code de Date C digo Fecha MOVABLE HEATER MEUBLE CHAUFFANT C...

Page 4: ...with citrus oil based product and buff with a clean soft cloth DO NOT use brass polish or household cleaners as these products will damage the metal trim Citrus oil based products can be obtained at...

Page 5: ...on Remote Receiver Control Panel NOTE Please operate the remote transmitter at a slow measured pace Press the remote control buttons with an even motion and gentle pressure Repeatedly pressing buttons...

Page 6: ...are 5 brightness levels that can be selected and OFF 00 setting Settings F5 F1 decrease in brightness Pressing the timer button will cycle through the timer settings 30 minutes 1 Hour 2H 3H 4H 5H 6H 7...

Page 7: ...ord was not plugged into the outlet 4 Check that unit is plugged directly into a standard 120 volt outlet 5 Stove does not turn on manually 5a No incoming power from the electrical wall socket or butt...

Page 8: ...Inquriy 14 It is safe to place unit on carpet but make sure any flammable items are at least 3 feet away from front and sides of the unit 15 How many square feet will my unit warm up 15 Product Inquri...

Page 9: ...nerator Drive Motor Y16 S174 P10 3 Door Pull Y16 S176 DP 4 Control Panel Circuit Board Y16 S176 P32 5 Heater Blower Assembly Y15 S176 P01 6 Stove legs SL 5020 BLK DFI 5020 01 SL 5020 BRZ DFI 5020 02 S...

Page 10: ...is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may...

Page 11: ...or same 6 The owner user assumes all other risks if any including the risk of any direct indirect or consequential loss or damage arising out of the use or inability to use the product except as provi...

Page 12: ...www tsicustomerservice com A606 12 www tsicustomerservice com...