TROUBLESHOOTING 

Problem

Root Cause

Corrective Action

Display shows “        ”

The thermostat sensor is

broken or disconnected.

Unplug the fireplace, remove the back panel of the fireplace and check that 

the thermostat is plugged into the main circuit board. If this does not solve 

the problem contact customer service for a replacement thermostat sensor.

Display shows “        ”

The thermostat sensor is 

broken.

Contact customer service for a replacement thermostat sensor. 

Display shows “       ”

Manual Reset overheat

protection has triggered.

Inspect the heater and check that the air inlets and outlets are not blocked 

as this may cause overheating. Unplug the heater for 30 minutes and allow 

it to cool down. Replug and operate, monitor the heater for signs of 

overheating, if the problem persist discontinue use of the heater and 

contact customer service.

Display shows “       ”

Normal operation.

Check your heater cord and plug connections. Faulty wall outlet 

connections or loose plugs can cause the outlet or plug to overheat. Be 

sure the plug fits tight in the outlet. Heaters draw more current than small 

appliances, overheating of the outlet may occur even if it has not occurred 

with the use of other appliances.  During use check frequently to determine 

if your plug outlet or faceplate is HOT!  If so, discontinue use of the heater 

and have a qualified electrician check and/or replace the faulty outlet(s).

Heater does not blow 

warm air.

Cool down cycle.

Normal operation, will continue to run for several minutes before shutting 

down.  Times will vary based on temperatures. During this time cool air 

will blow.

No power, logs do not

glow.

No power to the unit

Check that unit is plugged into a standard 120V outlet. Press power button 

several times, make sure power is set at “ON”position.

Logs glow, but no

flame effect.

Flame effect turned off

Press flame button several times.

Heater does not blow

warm air.

Thermostat setting is 

preventing heater from 

turning on.

Adjust the temperature settings to ensure that the thermostat is set higher 

than the current room temperature.

Flame effect works but 

heater function does 

not and the emberbed 

flashes when the heater 

button is pressed.

The heater is disabled.

With the power on press and hold the POWER button on the control panel 

for 10 seconds. Once re-enabled the emberbed lights will flash multiple 

times.

Remote Control is not 

working.

No batteries

Change the remote batteries.

Poor Signal

Operate remote transmitter at a slow measured pace. 

Press the remote control buttons with an even motion  and gentle pressure. 

Repeatedly pressing buttons in rapid succession may cause the transmitter 

to malfunction.

Distance

Operate the remote at a distance less than 20 feet from the front of the 

appliance; point the remote at the control panel.

Summary of Contents for 23II800GRA

Page 1: ...www tsicustomerservice com A331 1 Twin Star International Inc Delray Beach FL 33445 Made in China Printed in China www tsicustomerservice com 1 888 674 7517 MODEL 23IRM5736 INSERT MODEL 23II800GRA...

Page 2: ...service 3 Go to www tsicustomerservice com for product warranty registration If you are unable to complete registration save your proof of purchase for warranty purposes Model Mod le Modelo 23II800GRA...

Page 3: ...immediately turn the heater off and inspect for any objects on or adjacent to the heater that may cause high temperatures DO NOT OPERATE THE HEATER WITH THE ALARM FLASHING 1 Read all instructions befo...

Page 4: ...www tsicustomerservice com A331 4 Control Panel Display OPERATION INSTRUCTIONS The heater can be operated by either the remote control or the control panel...

Page 5: ...effect so that it works without heat press the heater button until the display shows 00 The thermostat is adjustable by 2 F or 1 C increments The up and down buttons on the remote will increase decre...

Page 6: ...is HOT If so discontinue use of the heater and have a qualified electrician check and or replace the faulty outlet s Heater does not blow warm air Cool down cycle Normal operation will continue to run...

Page 7: ...15 The motors used on the fan and the flame generator assembly are pre lubricated for extended bearing life and require no further lubrication However we recommend periodic cleaning vacuuming of the f...

Page 8: ...limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not install...

Page 9: ...assumes all other risks if any including the risk of any direct indirect or consequential loss or damage arising out of the use or inability to use the product except as provided by law 7 All other w...

Page 10: ...www tsicustomerservice com A331 10 www tsicustomerservice com...

Reviews: