![Dupla Twin-Control Using Instruction Download Page 22](http://html1.mh-extra.com/html/dupla/twin-control/twin-control_using-instruction_2540154022.webp)
22
5.4.2 Setting as second temperature
After acknowleding flashing
SET
by pressing
, flashes .
If temperature 1 on slot 1 and temperature 2 on slot 2 both are programmed in the HEAT mode, the value is the
fixed difference of temperature 1 (water heating) and temperature 2 (floor heating), and cannot be changed . Simply
confirm with
, to procees with the next programming point 5 .4 .3 .
Is temperature 1 on slot 1 programmed in the HEAT mode and the COOL mode for temperature 2 on slot 2 selected,
with the
▲
or
▼
button between 0 .1 and 5 .0 °C a higher than the water temperature can be chosen and acknow-
ledged with
, from that on the cooling is enabled .
Caution:
Avoid to set a too low difference or no difference ( ) of the heating and cooling temperature so
that heating and cooling units are not short changing or active at the same time.
Advice:
Theoretically water c water heating (slot 1: Temp
1
COOL / slot 2: Temp
2
HEAT) is possible
but makes no sense. Temperature 2 in heat mode is fixed at 0.1 °C higher than temperature 1 even slot 2 is in
heating mode.
5.4.3 Alarm setting temperature 2
After confirming a flashing , flashes . Use the
▲
or
▼
button to set the +/- alarm between 0 .1 °C and 10 °C .
Press the
button to confirm .
Advice:
means that the alarm has not been set.