48
Status indicator light meaning
Condition
Arc power indicator light
Circular status indicator light
Remarks
E-stop
Red often on
Red often on
Standby
Blue breathing lamp
Blue breathing lamp
Prepare for
charging
Green often on
Green often on
Simple one has no this
state
Charging
Green often on
Green breathing lamp
End of
charging
Green often on
Blue often on
Individual models have
no this state
Electric leakage
Red breathing lamp
Red breathing lamp
Over voltage
Less voltage
Red often on
Blue often on
Over current
protection
Red often on
Green often on
Over
temperature
protection
Red often on
Blue breathing lamp
Hardware
failure
Red often on
Green breathing lamp
Power off
Not bright
Not bright
Maintenance Notes
Check whether the line is aging with the monthly power cut .
Conduct leakage test on the e
x
ternal leakage protector to ensure the normal operation
of the leakage protector.
Oberve incoming lines to make sure no wires is damaged.