background image

ZN.3070.C7

2 of required
Fascia Board

E

Double door 45mm

 

1 of required

F.1630

40 of required
Roof Board

F.3000

40 of required
Roof Board

F.4270

38 of required
Floor Board
(Inc. one spare)

AP.45.4500.O.A

2 of required
Apex

Z.195.A

2 of required
Trapezoid

E

9

 - Window 45mm

 

1 of require

d

Casare 3545 (45mm) Components

Page 3

3070

19

9

6

ACCESSORIES

ITEM

QTY

35mm screw for securing door to first 3 wall 

logs, wind braces, roof edge reinforcements, 

apex trims, eaves edging and trapezoid, SMB 

brackets

200

50mm screws for fascias and double bearers 

40

55mm screws for floor trims

30

70mm screws for first full logs, door frame and 

purlins

30

M6 x 80mm bolts and nuts for storm braces

8

M6 25mm washers for storm braces

18

20mm screws for vents

9

40mm nails for floor and roof boards

640

SMB076 (45) Interlocking Window to Log 

Connecting Bracket

8

SMB078 (45) Interlocking Door to Log 

Connecting Bracket

16

Door handle set and accessories

1

Window handle set & accessories

1

Set of Vents 

2

1

Generic Assembly Instructions for Log Cabins

1630

3000

19

9

7

19

9

7

19

9

7

4500

120

45

4

4

6

19

1

9

5

4270

Summary of Contents for Carsare 35

Page 1: ...INSTALLATION MANUAL Carsare 35 45 45 mm Log Cabin Important If you have bought shingles please use our provided shingle installation instructions Unique Cabin Reference Number www dunsterhouse co uk ...

Page 2: ...00 70 70 0 18 of required Wall Log B45 310 70 0 0 1 of required Bottom wall log B45 1510 70 0 0 1 of required Bottom Wall log B45 3500 70 70 0 1 of required Bottom wall log A45 4500 70 70 0 35 of required Wall log Inc One spare Carsare 3545 45mm Components Page 1 3360 32 47 45 121 45 45 45 64 5 45 64 5 45 64 5 45 310 410 121 1510 121 3500 121 310 1510 3500 4500 45 121 ...

Page 3: ...d to be cut on site ZN 1700 C7 2 of required Fascia board HN 2000 4 of required Eaves Edging Required to be cut on site XN45 3500 70 70 0 C8 2 of required Top wall log P45 8RL 3500 65 65 0 4 of required Purlin P45 3500 65 65 0 1 of required Purlin Carsare 3545 45mm Components Page 2 1960 19 38 2000 19 38 2000 19 19 1700 19 96 2000 19 70 45 121 3500 3500 45 140 3500 45 140 ...

Page 4: ...s apex trims eaves edging and trapezoid SMB brackets 200 50mm screws for fascias and double bearers 40 55mm screws for floor trims 30 70mm screws for first full logs door frame and purlins 30 M6 x 80mm bolts and nuts for storm braces 8 M6 25mm washers for storm braces 18 20mm screws for vents 9 40mm nails for floor and roof boards 640 SMB076 45 Interlocking Window to Log Connecting Bracket 8 SMB07...

Page 5: ... this diagram To get more information on how to build this foundation system please refer to the main rapid pad assembly instructions All dimensions are approximate and subject to the limitations of the material used and the methods of manufacture Front Back Optional Rapid Pad Assembly Standard Bearers EN 3360 3360 680 600 600 600 600 600 680 4360 64 32 32 32 32 32 32 47 Fix the bearers together u...

Page 6: ...itations of the material used and the methods of manufacture Front Wall Rear Wall XN45 3500 70 70 0 C12 A45 3500 70 70 0 A45 310 70 0 0 A45 410 0 0 0 A45 1510 70 0 0 B45 310 70 0 0 B45 1510 70 0 0 A45 310 70 0 0 XN45 3500 70 70 0 C8 B45 3500 70 70 0 A45 3500 70 70 0 310 410 1680 310 3500 3500 790 ...

Page 7: ...arsare 35 45 45mm All dimensions are approximate and subject to the limitations of the material used and the methods of manufacture Side Wall Side Wall AP 45 4500 O A A45 4500 70 70 0 AP 45 4500 O A A45 4500 70 70 0 4500 4500 ...

Page 8: ...nsions are approximate and subject to the limitations of the material used and the methods of manufacture P45 3500 65 65 0 P45 8RL 3500 65 65 0 P45 8RL 3500 65 65 0 ZN 3070 C7 N 2000 ZN 1700 C7 HN 2000 N 2000 Z 195 A Z 195 A ZN 1700 C7 N 2000 ZN 3070 C7 N 2000 HN 2000 ...

Page 9: ...roof insulation 150 Diameter 3x20mm Screws for metal brackets 50 Metal brackets 12 P Board required to be cut on site K Board required to be cut on site K Board off cut K Board required to be cut on site A Board A Board 2500 625 3500 1250 380 500 1250 1250 3000 1630 375 P Board required to be cut on site K Board required to be cut on site P Board off cut Roof Insulation Panel Layout for Premium Pl...

Reviews: