70 … 76
MC • Edition 2022.08 • No
. 279 663 R
ev
. -0
71 … 76
16. Flow diagram
15.3 Storage conditions
Basically, DIN 7716 (guidelines for storage, maintenance
and cleaning of rubber products) applies to the storage of
diaphragms and O-Rings.
The ageing process depends
mainly on the following factors:
• Temperature
• Thermal radiation
•
Solar radiation
•
Humidity
•
Relative humidity
•
Ozone
•
Stress condition of the component
Proper storage
•
Storage temperature between 5 °C and 20 °C
•
No direct solar radiation
•
No direct heat sources in the storage area
•
No exposure to ozone
•
Tension-free storage
•
Storage in polyethylene bags
•
Do not exceed the max. storage periods of 3 years.
p
d
Flow volume
[
Nm
3
/h
]
p
d
-10%
p
d
+10%
max. flow volume (AC 10)
p
d
Setpoint
min. flow volume (AC 10)*
* min. flow volume = 0.1 * max. flow volume
SZ10
Flow diagram AC10: Please, refer to document number. 288127 “Flow diagrams FRM-NOC”.
16.1 Flow diagrams AC 10 explanation
Summary of Contents for FRM-NOC 100025 HD
Page 17: ...MC Edition 2022 08 No 279 663 Rev 0 17 76 A B C D E A B C D E F Type UHD F Type HD...
Page 66: ...66 76 MC Edition 2022 08 No 279 663 Rev 0 14 4 Tools required A B C2 D C1...
Page 74: ...74 76 MC Edition 2022 08 No 279 663 Rev 0...