Dungs EMP-5 Installation Instruction Download Page 9

9 … 9

8 … 9

MC • Karl Dungs

, Inc.

 • EMP-5 • Edition 2017.05 • P/N 261483

Model #

Description

Order No .

CP-9302-702

4 - 20 mA current to position converter (black box) 

(comes standard)

269229

AM-321-0-2

Auxiliary feedback switch. Two independent SPDT 

snap switches for position feedback

269234

ADDA-259-010

135 ohm slidewire; 90 deg

267194

ADDA-274-010

1000 ohm slidewire; 90 deg

Note: Actuator will not operate in the same way

269221

ADDA-38-010

100 ohm slidewire; 180 deg

269241

ADDA-902-5

100 ohm 90 deg slidewire and wiper arm kit

269220

AM 332-102-1

100 Slidewire potentiometer for position indicat-

ing or paralleling (same housing as AM 321-0-2)

269236

AM 301

90 deg mounting bracket

267191

AE 504

Paralleling Relay for driving up to 3 actuators with 

one input signal

269237

AM 132

5/16” hole; ball joint linkage-swivel connector for 

non-parallel linking

269232

AM 122

5/16” hole; straight linkage connector for parallel 

linking

269233

AM 113

1/2” crank arm (comes standard)

267224

AM 116

1/2” splined crank arm (not shown)

267242

AM 125

5/16” diameter rod (20”long)

267223

AM 363

NEMA 4 Cover (comes standard)

269239

Accessories & Replacement

Karl Dungs GmbH & Co . KG

P .O . Box 12 29

D-73602 Schorndorf, Germany

Phone  +49 (0)7181-804-0

Fax  +49 (0)7181-804-166

e-mail info@dungs .com

Internet http://www .dungs .com

Karl Dungs, Inc .

3890 Pheasant Ridge Drive NE

Suite 150

Blaine, MN 55449, U .S .A .

Phone 763 582-1700

Fax  763 582-1799

e-mail info@karldungsusa .com

Internet http://www .dungs .com/usa/

We reserve the right to make modifications in the course of technical development.

Summary of Contents for EMP-5

Page 1: ...n be foreinstallingoroperating Keep theinstructioninasafeplace You find the instruction also at www dungs com If these instructions are not heeded the result may be personal injury or damage to proper...

Page 2: ...ning 34 8 A locked rotor Grounded Input Grounding either or both input wires will not cause Fuse There is no internal fuse The EMP is impedence protected Model No Order No Travel Description Timing se...

Page 3: ...e them off and safely stow away Replacing EMP 3 or EMP 4 with EMP 5 When replacing an EMP 3 or EMP 4 with an EMP 5 and if the high fire override is not used then follow the wiring schematic EMP 4 to E...

Page 4: ...oltage to terminals input leads or to X 2 3 4 7 or 8 will permanently damage the motor Field Wiring Terminal Block Internal Wiring Low Voltage Leads for Driving Actuator 4 20 mAdc Controller Input Sli...

Page 5: ...wise end of actuator rotation Each click of the cam represents about 3 change in operating point NOTE After turning the disc remove back plate and reposition the wiper it will need to be repositioned...

Page 6: ...e mA input equals the desired finish point maximum position This is typically 20 mA 3 With the desired current input for maximum position typi cally 20mA the actuator will drive towards 90 degrees Onc...

Page 7: ...ading windings The voltage on the shading windings is about 30 VAC and the voltage on the main windings is 120 VAC Tech Tip 2 Maximum voltage to terminals 7 and 8 is 24 VAC During operation the voltag...

Page 8: ...7 05 P N 261483 Mounting holes 3 17 64 6 7 mm Dia 3 1 4 83 mm 4 3 4 121 mm 4 102 mm Shaft Dia 1 2 13 mm 2 1 4 57 mm 1 5 8 41 mm 2 1 4 57 mm 4 102 mm 2 51 mm 1 8 3 mm 7 1 4 184 mm 2 3 4 70 mm 2 1 4 57...

Page 9: ...267191 AE 504 Paralleling Relay for driving up to 3 actuators with one input signal 269237 AM 132 5 16 hole ball joint linkage swivel connector for non parallel linking 269232 AM 122 5 16 hole straigh...

Reviews: