Commisioning Phasing Cylinders (continued)
3. Fault Finding (continued)
2. Cylinders moving at different rates
(a) Check that there is no air in the system. Raise and lower the machine; all cylinders should move at the
same time, any lag indicates that there is air in the system. Re-bleed the system if necessary.
(b) Ensure that the cylinders have been connected correctly. The cylinders should be connected in series
so that the bore sizes go down in 1/4” increments. The Rod end port of the master cylinder (3.5” bore) is
connected to the piston end port of the slave cylinder (3.25” bore).
‘Renovator AS3000/3500’
Phasing Cylinders