35
Pt. No. 67396
Issue 0119
‘Renovator AS3000/3500’
Jackal Areameter
Farmscan Jackal v3 Settings Setup
Refer to the manual supplied with your Farmscan Jackal kit for information and operation.
Farmscan Jackal v3 Factory Setup for Enviro DD30 Air
Refer to pages 6,9,11 of the Farmscan Jackal v3 manual.
Input 2
-Two wire ‘reed’ sensor for ‘Area/Speed Wheel’ measurement taken from shaft on drive
pedestal.
The white ‘signal’ lead is connected to input A2.
Input 3
- Three wire ‘reed’ sensor for fan ‘Tachometer’
measurement. The white ‘signal’ lead is connected to input A3.
Refer to the Farmscan manual if you want to make additional sensor connections.
It is advisable, as with all things electronic, to have a backup of your totals. We suggest you record
these on a daily basis in a notebook or diary.
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10 A11
A3 Signal
A7 Gnd
A9 +12v
A7 Gnd
A2 Signal
Connect to Fan RPM
3 Wire Sensor via extension
cable.
Connect to Pedestal Shaft
2 Wire Sensor via extension
cable.
Connect directly
to Tractor Battery
+12v
0v
Input 2 Edit
m/pulse
Auto Set:
Target:0.000m
Meas.pulses:
0
Manual Ratio:
2.750000
NEXT
EDIT
Other Settings
Implement Width:
3.000 m
Extern.Run/Hold:
Disabled
Alarm Beep:2
NEXT
EDIT
Input 3 Edit
pulse/rev
Auto Set:
Target:0.000rev
Meas.pulses:
0
Manual Ratio:
1.000000
NEXT
EDIT
red
red
black
black
white
white
black
Machine
Size
Row Spacing
(mm)
Sowing Width
(m)
16 Run
178
2.848
20 Run
178
3.560
21 Run
147.5
3.098
24 Run
147.5
3.540
24 Run
125
3.000
28 Run
125
3.500
Summary of Contents for Enviro DD30
Page 2: ......
Page 6: ...4 ...
Page 38: ...36 ...
Page 39: ...37 Pt No 67396 Issue 0119 Renovator AS3000 3500 Calibration Notes ...
Page 48: ...46 Renovator AS3000 3500 Maintenance Notes ...
Page 49: ...47 Pt No 67396 Issue 0119 ...
Page 50: ...48 ...
Page 52: ...50 Renovator AS3000 3500 Complete Assembly 7 8 14 11 6 4 5 9 1 2 3 10 ...
Page 76: ...74 Renovator AS3000 3500 Metering Unit 3 1 2 9 2 9 5 8 7 5 6 4 ...
Page 80: ...78 ...