1. FUSE HOLDER:
The fuse is located in the cap of the fuse holder. If the fuse
fails, it must be replaced with one that provides proper current protection or you
will void the warranty. The proper fuse rating for the 110-120 v.a.c. Convertible
60 Watt Amp is 3.15
amp Slo -Blo @ 250 v.a.c.
Before removing the fuse cap, UNPLUG
THE POWER CORD FROM THE WALL
A.C. OUTLET. After checking the fuse and replacing the cap, you can plug the
amp back into the wall.
To remove the fuse cap, simply use a small blade screwdriver and turn the cap
counterclockwise. To replace the fuse cap, make sure the fuse is snugly seated
in the cap, push fuse and cap into the fuse hole, and turn the fuse cap clockwise
using a small blade screwdriver.
Fuses do not wear out; they do not deteriorate with age. Fuses are protection
devices that protect the electronics from damage if there is a serious electrical
problem. If your amp repeatedly has fuse failures, check pages 1415 for the
troubleshooting tips.