Figure 3 APARTMENT MVHR OPERATIONAL SCHEMATIC 

 

MVHR (MECHANICAL VENTILATION WITH HEAT RECOVERY) PROVIDES FRESH FILTERED AIR INTO A 

BUILDING WHILST RETAINING MOST OF THE ENERGY THAT HAS ALREADY BEEN USED IN HEATING 

THE BUILDING. HEAT RECOVERY VENTILATION IS THE SOLUTION TO THE VENTILATION NEEDS OF 

ENERGY EFFICIENT BUILDINGS. MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR), HEAT 

RECOVERY VENTILATION (HRV) OR COMFORT VENTILATION ARE ALL NAMES FOR THE SAME 

THING. A HEAT RECOVERY VENTILATION SYSTEM PROPERLY FITTED INTO A HOUSE PROVIDES A 

CONSTANT SUPPLY OF FRESH FILTERED AIR, MAINTAINING THE AIR QUALITY WHILST BEING 

PRACTICALLY IMPERCEPTIBLE. 

MVHR WORKS QUITE SIMPLY BY EXTRACTING THE AIR FROM THE POLLUTED SOURCES E.G. KITCHEN, 

BATHROOM, TOILETS AND UTILITY ROOMS AND SUPPLYING AIR TO THE ‘LIVING’ ROOMS E.G. 

BEDROOMS, LIVING ROOMS, STUDIES ETC. THE EXTRACTED AIR IS TAKEN THROUGH A CENTRAL 

HEAT EXCHANGER AND THE HEAT RECOVERED INTO THE SUPPLY AIR. THIS WORKS BOTH WAYS, IF 

THE AIR TEMPERATURE INSIDE THE BUILDING IS COLDER THAN THE OUTSIDE AIR TEMPERATURE 

THEN THE COOLING IS MAINTAINED IN THE BUILDING. 

 

 

Summary of Contents for MRXBOXAB-ECO2

Page 1: ......

Page 2: ...TABLE OF CONTENTS 0 INTRODUCTION 1 1 0 APARTMENT VENTILATION 3 2 0 OPERATIONAL GUIDE 5 2 1 Filter and Routine Maintenance 5 2 2 Filter Maintenance 6 2 3 Routine Maintenance 6 2 4 Technical Support 6 ...

Page 3: ...ATION SYSTEM INSTALLED THAT EXTRACTS AIR FROM THE BATHROOMS AND KITCHEN AREA AND RECYCLES THE HEAT TO SUPPLY FRESH AIR TO THE LIVING ROOM AND BEDROOMS THIS VENTILATION IS ALWAYS ON TO ENSURE THAT THE APARTMENT IS ALWAYS VENTILATED THE HEAT RECOVERY IN THE UNIT AND THE HIGH PERFORMANCE WALLS AND WINDOWS MEAN THAT VERY LITTLE HEATING IS NEEDED IN THE APARTMENT Model MRXBOXAB ECO2 Location Utility Cu...

Page 4: ...2 P a g e ...

Page 5: ... the extracted air previously pre filtered When the integrated humidity sensor detects a higher humidity than the one set up in the system it will turn on the Boost extract fan in the bathroom Kitchen areas The boost extract fan will remain on until the humidity has gone below the setpoint The unit will also turn into Boost mode when light switches in Bathrooms and Kitchen are turned on MVHR suppl...

Page 6: ...R THE SAME THING A HEAT RECOVERY VENTILATION SYSTEM PROPERLY FITTED INTO A HOUSE PROVIDES A CONSTANT SUPPLY OF FRESH FILTERED AIR MAINTAINING THE AIR QUALITY WHILST BEING PRACTICALLY IMPERCEPTIBLE MVHR WORKS QUITE SIMPLY BY EXTRACTING THE AIR FROM THE POLLUTED SOURCES E G KITCHEN BATHROOM TOILETS AND UTILITY ROOMS AND SUPPLYING AIR TO THE LIVING ROOMS E G BEDROOMS LIVING ROOMS STUDIES ETC THE EXTR...

Page 7: ...stems NOT AIR CONDITIONING SYSTEM It offers the highest level of comfort and control available Note The most common concern with home owners is that heat ventilation devices create noise With Advance absolute optimization of every element does everything possible to minimize generation and transmission of both motor and airflow noise Important Unit must not be switched off product is designed to r...

Page 8: ...e 2 filter Covers Remove filters by pulling the black tab Vacuum the filters or replace them Replace in reverse order If the filters need to be replaced contact Nuaire Sales by calling 029 2085 8200 quoting the model reference The product should be professionally serviced every two years 2 3 Routine Maintenance Cleaning Exterior For best results use a clean cloth and warm water with a mild deterge...

Reviews: