Refrigeration System Replacement

General

Figure 6

Location of Refrigeration Assembly

The refrigeration system assembly is located in
the front of the unit, (Figure 6).

1. Disconnect unit from power source.

2. Remove vent cover.

3. Using a refrigeration-charging unit, evacuate

refrigerant from the system according to
Duke Manufacturing Service Bulletin
Number 26.

4. Remove expansion valve and evaporator

tubing from refrigeration assembly.

5. Remove refrigeration assembly mounting

hardware.

6. Tag and disconnect wiring at junction box.

7. Slide out refrigeration assembly through

vent.

8. Thoroughly clean the refrigeration assembly

compartment.

NOTE:

Before installing replacement

refrigeration assembly, pressure check
evaporator coils for leaks.

9. Install replacement refrigeration assembly

onto slide bars.

10. Slide in refrigeration assembly to original

position.

11. Install refrigeration assembly mounting

hardware.

12. Install expansion valve and evaporator

tubing from refrigeration assembly.

13. Using tags, connect wiring at junction box.

14. Connect unit to power source and test unit.

15. Charge system according to Duke

Manufacturing Service Bulletin Number 26.

16. Install vent cover.

Recharging Refrigeration System

General

To analyze the performance of a refrigeration
system, temperature readings are recorded and
converted to pressure readings using a standard
pressure/temperature chart.

When it is necessary to service a factory sealed
refrigeration system and return it to its properly
sealed condition, strictly adhere to the following
approved procedure.

Tools

Standard hand and refrigeration tools

Refrigerant Type: R-134A, 4.5 ounces

Summary of Contents for SUB-GP

Page 1: ...Duke is a registered trademark of the Duke Manufacturing Company Duke Manufacturing Company 2305 N Broadway St Louis MO 63102 Phone 314 231 1130 Toll Free 1 800 735 3853 Fax 314 231 5074 www dukemfg c...

Page 2: ...E OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING UNLESS ALL COVER AND ACCESS PANELS ARE IN PLACE AND PROPERLY SECURED DO NOT OPERATE THIS EQUIPMENT CAUTION...

Page 3: ...nnection 4 MAINTENANCE 5 Stainless Steel Care and Cleaning 5 PREVENTIVE MAINTENANCE 6 Cleaning the Condenser Coil 6 PARTS REPLACEMENT 7 Thermostat Replacement 7 General 7 Evaporator 7 General 7 Refrig...

Page 4: ...Be sure that the unit is placed on a firm flat surface floor Check for cracks in flooring or tile and avoid these areas if possible If necessary place support pads properly rated for the weight of th...

Page 5: ...trial cleaners and also in hard water and salts If a chloride or alkaline cleaner has been used rinse repeatedly and dry thoroughly Always use only soft cloths or plastic scouring pads For routine cle...

Page 6: ...or near the condenser coil 9 8 765 4 3 2 1 WARMER COLDER Figure 3 Location of Condensing Coil The condenser coil is located and accessed from the front of the unit Figure 3 A vent cover protects the...

Page 7: ...m evaporator coil 5 Remove knob 6 Remove thermostat mounting screws 7 Remove thermostat from control panel 8 Install replacement thermostat mounting screws and knob NOTE Do not kink thermostat probe 9...

Page 8: ...ly pressure check evaporator coils for leaks 9 Install replacement refrigeration assembly onto slide bars 10 Slide in refrigeration assembly to original position 11 Install refrigeration assembly moun...

Page 9: ...l injury or death When using nitrogen to pressure test always use a pressure regulator Failure to do so will result in extremely high pressure of the compressor or other system components and result i...

Page 10: ...Service Manual for Tri Channel Cold Pan SUB GP 10 ELECTRICAL Electrical Schematic Figure 7 Electrical Schematic...

Page 11: ...ostat switch is stuck in the closed position Drain hose plugged Drain hose loose or disconnected from drain pan REMEDY Plug unit in Set thermostat to a higher number for a colder temperature Replace t...

Reviews:

Related manuals for SUB-GP