Figure 2 – Electronic board of EzyMegaCAM

POF

 (connector side)

 

 
 
 
 
 

POWER SUPPLY 

The camera can be powered: 

 

power supply 12 ÷ 30 V 

       or         power supply 24 V 

 

 

The 

POWER

 connector does not have preferential polarity (even in case of CC) 

POWER 

BAT 

Backup battery 

connector 

POF1 LED 

Network activity 

MASTER slot 

Lower slot 

 

Use ONLY this one 

in case of single SD 

card 

SLAVE slot 

Upper slot 
 
DO NOT use in case 
of single SD card 

Double SD slot 

To install up to 

two SD cards 

(must be 

identical). 

Insert/remove 

only with device 

completely 

unpowered 

Input/Output 

Use provided cable

 

POF1 

Plastic optic fiber 

connector (LAN) 

POF2 

Plastic optic fiber 

connector (LAN) 

POF2 LED 

Network activity 

Summary of Contents for EzyDriveCAM

Page 1: ...requirements European Union EzyDrive EzyDrive EzyDrive EzyDriveCAM D I G I T A L V I D E O R E C O R D E R HARDWARE INSTALLATION MANUAL VERSION 3 0 Software manual only on CD This manual may be subje...

Page 2: ...with recording storage on board that can be questioned by a vision and programming software EzyViewCAM through locale network power line HomePlug system or remote connection WEB It can be visualized...

Page 3: ...wer over Ethernet system 12V GND BAT Backup battery connector LAN LAN connector RJ45 type Power supply 12 V Power 12 V Not necessary if using the PoE LAN system MASTER slot Lower slot Use ONLY this on...

Page 4: ...Backup battery connector POF1 LED Network activity MASTER slot Lower slot Use ONLY this one in case of single SD card SLAVE slot Upper slot DO NOT use in case of single SD card Double SD slot To insta...

Page 5: ...Y IS SWITCHED OFF POWER SUPPLY IS SWITCHED OFF POWER SUPPLY IS SWITCHED OFF POWER and DATA The camera is powered directly by 230 V power line Data communication from to the camera is made through powe...

Page 6: ...6 Input Output Figure 4 Input output connector and special cable scheme Connection of the input Figure 5 Connection scheme of the digital input to an external detector...

Page 7: ...7 Connection of the output Figure 6 Connection scheme of the digital output to a relay board to drive a load...

Page 8: ...d not through a LAN Program the camera then install and finally make some test and adjustments To program is required a PC with fixed IP address see network settings and EzyViewCAM software installed...

Page 9: ...unch EzyViewCAM software Set for each EzyCAM Site position and name IP address subnet and port Device password Once all parameters are set is possible to visualize EzyCAM by dragging its name in visua...

Page 10: ...s through the membrane that will be adapted automatically around the cables 2 2 2 2 Cable path break it following the form and pass the cable Connector on surface version Connect power and network cab...

Page 11: ...linking System initialization Off No power and low battery level System failure Link Active Solid or blinking LAN connection established Data transferring Off No connection 100 Mbps Solid Connection s...

Page 12: ...CAM Status Solid Onboard IR detector Blinking Blink about every 10 s system active waiting for an event Slow blinking on 1 s off 1 s system active and recording continuously Quick blinking system acti...

Page 13: ...ent Regions of Interest ROI adjustable in geometry and sensitivity Masking areas 1 masking area privacy zone adjustable in geometry Recording support Double memory slot Memory card type Secure Digital...