8.7
Distributor PCB
The distributor PCB is located at the back of the machine below the
clamping foot magnet. All control unit inputs and outputs are
accessible from here. The rear cover must be removed in order to gain
access to the terminals.
Description of the outputs
Output number
Output
Assignment
Y1 (FW/FK)
24V / 4 A
Thread clamp magnet / optional: Thread wiper
magnet
Y2
24V / 0.5 A
-
Y3
24V / 3 A
-
Y4 (FS)
24V / 4 A*
Thread tension magnet
Y5
24V / 0.5 A
Optional: Magnetic valve for the “separated
clamping foot 1"
Y6
24V / 0.5 A
Optional: Magnetic valve for the “separated
clamping foot 2"
Y7 - Y12
24V / 0.5 A
-
Y13 (FA)
24V / 3 A*
Thread trimmer magnet
Y14 - Y17
24V / 0.5 A
-
Y18 - Y19
24V / 6.5 A*
-
Y21 - Y23
24V / 0.2A
Optional: Laser marking light 1 –
3
Y24 - Y28
24V / 0.2A
-
Y31(X11/ X12: FL)
60V / 8A(2A)
Clamping foot magnet
*: Output is PWM-compatible
Magnets and magnetic valves are connected b24V (X9) and
the corresponding output (X8, X10).