7
3.3 Throat plate and its post
3.3.1 Description
The throat plate (1) is clamped to the throat plate post (2) with two
screws (3). Each sewing category (100, 200) has got its own throat
plate. They differ by the size of the piercing hole (4) and of the recess(5)
/the hook lock/.
3.3.2 Mounting and removing the throat plate
When mounting the throat plate (1), the finger of the hook (6) must fit
into the recess (5) of the throat plate.
Caution! Danger of injury!
Switch off the main switch! Before starting the setting
operation, wait until the motor stops!
- Turn slightly the finger (6) in the sense towards the throat plate (1).
- Place the throat plate (1) and screw in the screws (3).
3.3.3 Side setting of the throat plate post
The throat plate post (1) is to be set by its side (laterally) in such a way,
so that the axis of the piercing of the throat plate (2) is in the needle axis
(3).
Caution! Danger of injury!
Switch off the main switch! Before starting the setting
operation, wait until the motor stops!
- Loosen the screws (4 and 5) (from the rear side of the post as well).
- Shift the post (1) in the sense required.
- Tighten the screws (4 and 5) and check up for the correct setting.
2
3
2
6
3
4
3
5
1
1
4
2