Page 14
10. 230V power supply connection
230V
Protection fuse
5x20mm 1AT fast
230V
transformer
cir
cuit boar
d
motor
cover
cable clamp
230V
IMPORTANT:
before operating the door electrically ALWAYS ensure that the mechanical components, the
car and the anchor plate (see page 13) are engaged. The door must be in neither the open nor the closed
position.
Remove the plastic cover as shown in Figs. 42-43
Connect the 230 V 50/60 Hz power supply cable to the terminal located on the transformer.
See Fig. 44-45-46
A protection fuse is installed to protect the circuit board and the system. For your safety, it is essential to
use a cable clamp positioned where the cable passes through the hole in the steel plate supporting the
motor. See Fig. 46
IMPORTANT. DANGER: the 230V high voltage connection must
only be performed by a certified professional electrician.
Open the door manually to the desired maximum opening position.
At the car’s position on the rail, fix the mechanical end-of-travel stop as shown in the following drawings.
Important: tighten securely so that the end-of-travel stop does not move. When the end-of-travel stop is
correctly positioned, tighten the small central set screw (figs. 40-41).
When you operate your automation system, the door will close when the car touches and presses on the
open position end-of-travel stop.
9.
Adjusting the mechanical end-of-travel stop
car
rail
end of travel
end-of-travel stop
tighten securely
end-of-travel stop
Fig. 39
Fig. 40
Fig. 41
Fig. 42
Fig. 43
Fig. 46
Fig. 45
Fig. 44