Ducasa AVANT-DGP 1000 Operating And Installation Instructions Download Page 11

11

SETTING PROGRAMME AND CLOCK

To start programming press and hold 

CONFIG/PROG

 button for 3 seconds and the following screen will 

appear:

Programming starts on Monday at 00:00 and is set by choosing the required Mode for each hour of the 

week. Use the 

OK

 button to choose between Comfort , Economy or Frost Protection modes. On the screen, 

programme hours will show two blocks for Comfort, one block for Economy and no blocks for frost protection. 

After choosing the temperature mode press the 

+/-

 buttons to select the next hour to be programmed. When 

a full day has been programmed the screen moves to the next day. This is signified by a number from 1 to 7 

in the top left side of the screen.

Once each day of the week has been programmed the clock must be set. 

Once you have programmed 23:00 on day 7, the heater will automatically enter the time setting screen. 

To select the day of the week (1=Mon, 7=Sun) press the 

+/-

 buttons and confirm with the 

OK

 button. Next 

select the hour and confirm with 

OK

 button and then select the minutes and confirm pressing 

OK

 button once 

more.

KEYPAD LOCKING (ANTI-TAMPER)

The keypad can be locked to prevent any unauthorised person (children, people in public places, nurseries, 

offices, hotels etc.) altering the settings of the heater. To lock the keypad press and hold the + and – buttons 

at the same time for 3 seconds until “Lock” appears on the screen. 

Once set, any button presses will be ignored and “Lock” will be displayed on the screen.

To unlock keyboard, once again press and hold + and - for 3 seconds until the word ‘Lock’ disappears.

ADVANCED SETTINGS

To enter the advanced settings mode, press 

CONFIG

 button while the heater is in one of the main modes 

(OFF, AUTO, MANUAL). The following window will appear:

 

Now press the 

CONFIG

 button for 5 seconds and C1 appears on the screen. 

To select one of the advanced settings (C1 to C6) use the 

+/-

 buttons keys and choose the required mode 

by pressing 

OK 

button. The advanced settings are: 

1. C1-> Choose ºF or ºC 
2. C2-> Choose Type of Control 
3. C3-> Temperature Compensation 
4. C4-> Firmware Version 
5. C5-> Open Window Detection 
6. C6-> Eco-Start 

Summary of Contents for AVANT-DGP 1000

Page 1: ...ain for future reference Models AVANT DGP 350 AVANT DGP 500 AVANT DGP 750 AVANT DGP 1000 AVANT DGP 1250 AVANT DGP 1500 AVANT DGP 1800 NOTE A qualified electrician must carry out the electrical installation of this radiator The electrical installation must comply with the current UK regulations Any claim on the warranty could be invalid if these requirements have not been met ...

Page 2: ...IONS 9 CONTROLS 9 STAND BY FUNCTION 9 MAIN SWITCH 9 MODE SELECTION 10 CHARACTERISTICS 10 ADJUST PROGRAMMED TEMPERATURES 10 SETTING PROGRAMME AND CLOCK 11 KEYPAD LOCKING ANTI TAMPER 11 ADVANCED SETTINGS 11 HEATER RESET 13 QUICK GUIDE TO MANUAL PROGRAMMING 15 MAINTENANCE AND CARE 16 GUARANTEE 16 CORRECT DISPOSAL OF THIS PRODUCT 16 ...

Page 3: ...eminder to the user ATTENTION The heaters must not be covered by clothing containers or any other objects that may block the air ventilation VERY IMPORTANT The OFF indicator shown on the heater s control panel does not mean disconnection of the heater from the power supply and should be understood as a standby condition To ensure the heater is completely off and without access to the power supply ...

Page 4: ...place the heater directly on the floor Make sure that the wall where the heater is going to be mounted is suitable to bear the heater s weight Use the correct fixing for the type of wall the heater is to be mounted onto Make sure that the electrical power supply corresponds to the information indicated on the heaters rating label The heater must be levelled correctly both vertically and horizontal...

Page 5: ... the air circulation channels providing a very efficient convection effect Special heat conducting fluid in the aluminium body A unique process provides bubble free filling so that the fluid delivers warmth from the heating element in a totally uniform way ensuring that the entire surface of radiator provides comfortable heat Monotube heating element to ensure maximum heat output Designed and fabr...

Page 6: ...is positioned 10cm to the right of the apparatus and at 15cm above the floor According to regulations the apparatus must be connected to the power supply by means of an all pole circuit breaker with a contact gap of at least 3mm or by a thermal magnetic circuit breaker Location The ideal place to site the Ducasa radiator is as close as possible to coolest wall in the room but it is not recommended...

Page 7: ... sides Fig 1 Fig 2a Fig 3a Fig 2b Fig 3b Place the supports between the elements as shown in Figure 2a mark points on the walls through the fixing holes as shown in Figure 2b This determines the spacing of the supports Transfer these marks to whatever height above floor min 150mm that has been decided for the radiator Fix the supports to the wall with plugs and screws Be sure that the supports are...

Page 8: ...ig 4 FREE LOCKED As soon as the radiator is hanging on the supports press on the locking plate until a click is heard See Figure 4 The radiator is now installed 20mm Place the wall spacer as Figure 5 Fig 5 ...

Page 9: ...t it s in the on position After around 3 seconds the screen will show various information and the heater is ready to work Switching OFF Master To switch off the heater press the main On Off switch so that it s in the off position The LCD screen will be blank NOTE In the event of a power cut the current mode of operation and all set values including the program will be retained If the power cut las...

Page 10: ...he room temperature is lower than the set temperature the heating symbol will be shown indicating that the heater is producing heat When the room temperature equals or is above the set temperature the heating symbol will not be present indicating the heater is not producing heat ADJUST PROGRAMMED TEMPERATURES Adjusting the temperature in the following way will only affect the temperatures used for...

Page 11: ...OK button Next select the hour and confirm with OK button and then select the minutes and confirm pressing OK button once more KEYPAD LOCKING ANTI TAMPER The keypad can be locked to prevent any unauthorised person children people in public places nurseries offices hotels etc altering the settings of the heater To lock the keypad press and hold the and buttons at the same time for 3 seconds until L...

Page 12: ...50ºC and hysteresis of 0 75ºC To change the type of control press Confirm with the OK button The screens shown are Temperature Compensation C3 In this mode the display will alternate between the temperature compensation offset and the measured temperature with the offset applied Alter the offset with the buttons and confirm with the OK button Temperature compensation can be adjusted up to 3ºC Firm...

Page 13: ...ticular time The heater will monitor the room temperature over 10 days to establish how quickly the room reaches temperature and uses this information to switch the heater on at the correct time By reaching the required temperature at the set time and not before energy use and running costs are reduced By default this function is deactivated To change the status of the function press the button an...

Page 14: ...0 00037 kW 0 00037 kW 0 00037 kW 0 00037 kW 0 00037 kW In standby mode elSB 0 00037 kW 0 00037 kW 0 00037 kW 0 00037 kW 0 00037 kW 0 00037 kW 0 00037 kW Type of heat output room temperature control Electronic room temperature control plus week timer Other control options Room temperature control with open window detection With adaptive start control Heattend Products Ltd https www heattend co uk E...

Page 15: ...then press OK Use to set the hour then press OK Use to set the minute When you are happy the clock is correct press to move onto setting the temperatures Setting the Mode Temperatures Use to select then press OK Use to set the comfort temperature then press OK Use I to set the Economy temperature then press OK Use I to set the Frost Protection temperature then press Press OK until is shown on scre...

Page 16: ... your appliance please contact your supplier CORRECT DISPOSAL OF THIS PRODUCT Waste Electrical Electronic Equipment Applicable in the European Union and other European countries with separate collection systems This marking shown on the product or its literature indicates that it should not be disposed of with other household wastes at the end of its working life To prevent possible harm to the en...