background image

14

Always start the engine and let it stabilize before connecting any electronic devices.

Disconnect all electronic devices before stopping the engine.

WARNING!

Never start or stop engine with electrical devices plugged in to the receptacles.  Failure to

do so could damage the generator and / or connected electrical devices.

OPERATION

How to Stop Engine

Turn the ECO switch to the “OFF” position.

Disconnect any electronic device.  All loads

 MUST 

be disconnect from the generator.  Never start or stop the engine

with electrical devices plugged in to the receptacles.

Turn the 3 in 1 Start Switch to the “OFF” position.

Turn the Air Vent to the “OFF” position.

OFF

ON

CHOKE

How to Attach Electronic Devices

1. Before Starting generator

Make sure the generator is grounded (see page 10 for instructions).

Make sure the attached load is within the generator rated output  and the receptacle’s rated current.

Make sure all electrical cords and receptacles are in good condition.

Make sure all electronic devices are turned “OFF” before plugging them into the generator.

2. Start engine

3. If the attached load is small, turn the ECO switch to the “ON” position.  For a larger load, or if attaching multiple electronic   

devices turn the ECO switch to the “OFF” position.

4. Make sure the green AC pilot indicator light is on.

.

6. Allow generator output to stabilize (engine and attached devices run evenly) before plugging in the next load.

ON

OFF

节能

模式

关闭

开启

CH O K E

O N

O FF

Summary of Contents for D2000iS

Page 1: ...Model D2000iS Inverter Generator OPERATOR S MANUAL SAVE THIS MANUAL FOR FUTURE REFERENCE This manual contains important information regarding safety operation and maintenance ...

Page 2: ...nerator to an Electrical System 11 Adding Fuel 11 Adding Checking Oil 12 Operation 13 Grounding the Generator 13 How to Start Engine 13 How to Stop Engine 14 Attaching Electronic Devices 14 Charging a 12 Volt Battery 15 AC Parallel Operation 16 Don t Overload Generator 17 Wattage Reference Guide 17 Maintenance 18 Maintenance Schedule 18 Checking Spark Plug 19 Changing Oil 20 How to Clean Air Filte...

Page 3: ...ase Model Number Serial Number The emissions control system for this generator is compliant with all standards set by the Environmental Protection Agency Record the following information bellow for service or warranty assistance AC Output Rated AC Voltage Rated Frequency 5V DC 1 5A Rated Output Maximum Output 1800W Engine Displacement 80cc Engine Type Single cylinder 4 Stroke OHV Air Cooled Engine...

Page 4: ...result in serious injury or death WARNING Safety Instructions Using a generator indoors WILL KILL YOU IN MINUTES Carbon monoxide gas is a poisonous odorless gas that can cause headache confusion fatigue nausea fainting sickness seizures or death If you start to experience any of these symptoms IMMEDIATELY get fresh air and seek medical attention Install a battery operated carbon monoxide alarm nea...

Page 5: ... spark plug wire and make sure the fuel tank is empty with the 3 in 1 switch is turned to the off position WARNING Never exceed generators wattage amperage capacity This could damage the generator and or connected electrical devices WARNING Check operating voltage and frequency requirements of all electrical devices prior to plugging them into the generator To avoid recoil pull starter cord slowly...

Page 6: ...cord while standing in water while barefoot or when hands or feet are wet Always keep the generator dry Never operate generator in rain or under wet conditions Use a ground fault circuit interrupter GFCI in a damp or highly conductive area such as metal decking or steel work Never plug electronic devices into generator having frayed worn or bare wires Never touch bare wires or make contact with re...

Page 7: ... F Air Vent G Fuel Cap H Recoil Starter I Control Panel J Oil Warning Light K Overload Indicator Light L AC Pilot Light M 3 in 1 Start Switch RUN OFF and Choke N Economy Switch O USB Outlet 5VDC 1 5A P 230V AC Outlet N S O N S O P1 P Q P1 120V AC Outlet Q Parallel Outlets R Ground Terminal S 12V DC Port Q ...

Page 8: ...tarter Engine Overload Indicator Light If the engine overload indicator light comes on the generator s wattage amperage capacity has been exceeded by connected electrical devices or by a power surge When this occurs the green AC Pilot Indicator Light will go off The engine will continue to run but the red Engine Overload Indicator Light will stay on and power will no longer be supplied to connecte...

Page 9: ...ine ECO Control When the Engine ECO switch is turned to the ON position the economy control unit automatically determines the generator s proper engine speed based on the connected electronic load This results in superior fuel economy and reduces noise When the ECO switch is turned to the OFF position the engine runs at the rated speed of 4 850 r min Note The ECO switch must be turned to the OFF p...

Page 10: ...connect the generator to a driven ground rod Connect the ground terminal to the driven ground rod with a No 8 AWG American Wire Gage copper wire The wire connects to the terminal between the lock washer and nut Tighten the nut securely to ensure good connection Grounding the generator protects you from electric shock that results from a build up of static electricity or undetected ground faults On...

Page 11: ...rator produces a very high voltage which could result in burn or electrocution causing serious injury or death Connecting Generator to an Electrical System If connecting generator to a building s electrical system for standby power The power from the generator must be isolated from the circuit breaker or alternative power source The connection must comply with all electrical codes and applicable l...

Page 12: ...nd securely tighten before attempting to start the engine Insert a funnel into the crankcase dipstick hole and carefully add the specified amount of 4 Cycle engine oil SAE 10W 30 to empty reservoir until or oil reaches the outer edge of the oil fill hole crankcase dipstick hole To check oil set generator on a level surface wipe dipstick clean then reinsert dipstick without re threading Remove the ...

Page 13: ... the ON position Turn the 3 in 1 Start Switch to CHOKE Pull recoil handle starter cord slowly until resistance is felt then pull rapidly Let engine run for several seconds and then gradually as engine warms up turn the 3 in 1 Start Switch to the ON position Note To start the generator with the ECO switch in the ON position Disconnect all electrical loads from generator If ambient temperature is be...

Page 14: ...e Air Vent to the OFF position OFF ON CHOKE How to Attach Electronic Devices 1 Before Starting generator Make sure the generator is grounded see page 10 for instructions Make sure the attached load is within the generator rated output and the receptacle s rated current Make sure all electrical cords and receptacles are in good condition Make sure all electronic devices are turned OFF before pluggi...

Page 15: ...eck the gravity level of the electrode at least once per hour with a hydrometer to prevent overcharging and to test the battery s condition Be careful to follow the hydrometer manufacture s instruction Do not disconnect battery clamps while charging Batteries produce explosive gasses Disconnecting the battery clamps while charging could spark and ignite Do not charge battery in an enclosed area Ne...

Page 16: ...TION WARNING A faulty appliance or power cord can create an electric shock Do not use electronic devices that have a damaged cord or plug If an appliance begins to operate abnormally becomes sluggish or stalls turn off and disconnect appliance immediately The appliance may have a fault or its rated load capacity exceeds the power supply of the generator To avoid damage to generator or electronic d...

Page 17: ...0 Washing Machine 1150 3400 Gas Clothes Dryer 700 2500 Wattage Reference Guide Wattages listed are just approximations Check electronic device for actual wattage Don t Overload Generator Make sure you can supply enough rated watts for all electronic devices connected to the generator Rated watts refer to the power a generator must supply to keep a device running Surge watts refer to the power a ge...

Page 18: ...oose debris If dirt is caked on use a soft bristle brush Inspect the work area for hazards After Each Use Follow the following procedure after each use Shut off engine Store unit in a clean and dry area WARNING After First 5 Hours Change Oil After 8 Hours or Daily Clean Debris Check Engine Oil Level 6 Months 100 hr Use Check and Clean Air Filter Element Service more often under wet or dusty condit...

Page 19: ... a wire brush Check the electrode gap and slowly adjust to 0 7 0 8mm 0 028 0 031 in if necessary Reinstall spark plug and tighten to Torque 20 0Nm 14 8ft lb If spark plug is worn replace only with an equivalent replacement part Spark plug should be replaced annually Reconnect spark plug wire Replace spark plug cap then replace cap Standard Spark Plug E6TC E6RT BPR6HS Spark Plug Gap 0 7 0 8mm 0 028...

Page 20: ...enerator to collect used oil Allow oil to drain completely Return generator to a level surface Crankcase Dipstick hole Use a clean rag to wipe up any spilled oil Replace crankcase dipstick Reinstall outer casing and tighten screws Recommended Engine Oil SAE 10W 30 Recommended Engine Oil Grade API Service SE type or higher quality of engine oil Engine Oil Quantity 0 35L 0 924 US gal Make sure no fo...

Page 21: ...ement should be damp but not dripping Do not run the generator without reinstalling the foam element or excessive piston and cylinder wear may result CAUTION Remove screws then remove shown area of outer casing Install the outer casing and tighten the screws Allow hot components to cool before touching WARNING Avoid contacting hot areas of this unit Check the muffler screen and spark arrester for ...

Page 22: ...ts Remove any debris if obstructed Store indoors and use a protective cover to protect from dust FUEL For short term storage add fuel stabilizer to prevent stale fuel from causing acid and gum deposits in the fuel system and carburetor For long term storage drain the fuel ENGINE Remove spark plug Pour about 1 TBL of SAE 10W 30 engine oil into the spark plug hole then reinstall spark plug With the ...

Page 23: ...engine and let it run until it stops and all remaining fuel is consumed Do not connect electronic devices to generator during this process Remove outer casing screws then remove outer casing Turn the 3 in 1 switch to OFF Tighten the drain screw Install the outer casing and tighten screws When the engine has completely cooled down turn the Fuel Cap Air Vent to the OFF position MAINTENANCE CH O KE O...

Page 24: ...act service department 5 Contact service department Engine will not start shuts down during operation or starts and runs rough 1 3 in 1 switch set to OFF 4 Out of fuel or Stale fuel 5 Spark plug wire disconnected from spark plug 6 Bad spark plug 7 Water in fuel 8 Overchocking 9 Low oil level 11 Faulty ignition 1 Turn switch to CHOKE then pull recoil starter 4 Replace fuel 5 Reconnect spark plug wi...

Page 25: ... Output 12V 8A Overload Protect DC Non Fuse Protector AC Frequency Regulator Overload Protection Process Control Engine Engine DJ148F Engine Type Single Cylinder 4 Stroke Forced Air Cooling OHV Displacement 80cc Fuel Type Unleaded Gasoline Fuel Tank Capacity 4 5L Continued Running Time At Rated Power 4h Fuel Tank Capacity 350ml Spark Plug Model No E6TC E6RTC Starting Mode Recoil Starter Generator ...

Page 26: ...26 WIRING DIAGRAM W W P 2 1 3 4 ...

Page 27: ...27 WIRING DIAGRAM P 1 2 3 4 ...

Reviews: