Page 2
506695−01 11/10
Shipping and Packing List
Check the unit for shipping damage. If damaged, contact
the last shipping carrier.
1 Assembled outdoor unit
General
The 13HPD heat pump, which will also be referred to in this
instruction as the outdoor unit, uses HCFC−22 refrigerant.
This outdoor unit is intended as a replacement outdoor
component for use in residential systems which include an
existing indoor coil which is functioning properly. It is
NOT
intended for new installations.
shipped from the factory with nitrogen holding
charge that must be purged from the unit;
designed for use with HCFC−22 refrigerant only;
designed for use in systems that use check / thermal
expansion valve (CTXV). See the 13HPD product
specification sheet for approved check / expansion
valve match ups and application information.
Important
The heat pump must have properly matched
system components including indoor unit and refrigerant
metering device. Mismatched equipment may have an
impact on the operation, performance, reliability, and
warranty of the heat pump system.
Unit Dimensions − inches (mm)
SIDE VIEW
OUTDOOR COIL FAN
COMPRESSOR
VAPOR AND LIQUID LINE
CONNECTIONS
A
B
A
Discharge Air
SIDE VIEW
Model Number
A
B
13HPD−018−230
24−1/4 (616)
33−1/4 (845)
13HPD−024−230
24−1/4 (616)
33−1/4 (845)
13HPD−030−230
24−1/4 (616)
29−1/4 (743)
13HPD−036−230
24−1/4 (616)
33−1/4 (845)
13HPD−042−230
28−1/4 (616)
33−1/4 (845)
13HPD−048−230
28-1/4 (718)
37 (940)
13HPD−060−230
32-1/4 (819)
37 (940)