2.3. Maximum allowable pressures for the DualSun SPRING panel
CAUTION
It is imperative never to exceed the following pressures in DualSun panels
:
Maximum operating pressure = 1.5 bar
Maximum filling pressure = 2 bar
The maximum filling pressure corresponds to the allowable pressure in the panels, to purge
correctly the air during hydraulic commissioning.
The pressure can be raised to 2 bar for only a few minutes
.
At the end of commissioning
of the installation, the maximum operating pressure to be ob-
served is
1,5 bar
.
The temperature of the panels must be between 10 and 45 ° C during commissioning.
Installation, use, maintenance manual - DualSun solar heating system for individual
swimming pools
8