General Use

• Open and close the lance trigger to start/stop the flow of water as required.

•  The washer is fitted with a return-to-tank pressure regulating valve which bypasses 

excess fluid back to the supply tank during normal use and when the lance trigger is 
closed

NOTE – It is normal for a small amount of water to be bypassing even when the lance 
trigger is open.

•  The pressure can be adjusted using the pressure adjusting knob (item 6, fig 1) on the 

pressure regulating valve.

• The Washer is supplied with a selection of nozzles to give different fluid projection.

Warning – Risk of damage to pump

Do not let the pump idle in bypass for long periods of time. Never leave the 
Washer running unattended.

!

!

7

Warning

Stopping the Pump

•  Always make sure that, once stop operations have been performed, no part of the motor 

pump and of the machine in which it is integrated is moving and no pipes contain liquid 
under pressure.

a)  Turn off the delivery pressure as described in point a) in “Pump Operation” section.

b) Stop the pump.

c) Wait for the motor pump and the machine in which it is integrated to cool down.

7. Operating Information

Initial Priming

•  Ensure the suction filter is fully submerged in the supply tank
•  Hold lance trigger open and wait for water to make it’s way up the suction hose and in to 

the Washer.

• After initial priming from the water supply tank the Washer is ready to run.

Pump Operation

•  The motor pump can only be primed if the pressure of the delivery circuit is reset in the 

following way:

a) Fully turn the knob of the regulation valve (item 6, figure 1) anti-clockwise.

b) Start the pump to prime it.

c)  Turn the knob (item 6, figure 1) until the water is delivered at the required pressure (turn 

clockwise to increase the pressure, turn anti-clockwise to decrease the pressure)

Summary of Contents for SprayWash SW116PHR

Page 1: ...C M Y CM MY CY CMY K spraywash215x75 pdf 1 21 08 2018 09 03 20 Product id serial number information 793 1208 SW116PHR Washer User Manual...

Page 2: ...ual highlights certain safety measures which should be taken in to consideration when using the Washer However each contractor and operator should make their own risk assessments whilst considering th...

Page 3: ...se Warning The Washer is performance set at factory Do not adjust the engine governor or Washer valves unless qualified to do so Over loading of engine and components can lead to equipment failure per...

Page 4: ...d Levels Uncertainty K 1 dB SPL LWA dB 62 GSPL LWA dB 99 Oils Pump Oil ENI Blasia S 150 ISO L CKD Gearbox Oil ENI Grease MU EP Engine Oil Refer to engine user manual W D Dimensions 900L x 600W x 700H...

Page 5: ...l kinds and types inflammable liquids or liquefied gases edible liquids solvents and thinners of all kinds and types paints of all kinds and types liquids with temperatures above 40 C 104 F or below 5...

Page 6: ...nozzles Figure 2 Standard accessories 4 Component Accessory Identification Figure 1 Washer Components 1 Trolley with 10 wheels 2 Engine 3 Pump 4 Mounting Flange Gearbox 5 Pump oil filler cap 6 Pressur...

Page 7: ...sher to aid priming and water supply Ensure the filter is always below the water level Connect the bypass hose item 11 fig 2 to the bypass outlet on the pressure regulating valve item 9 fig 1 and put...

Page 8: ...4 Choke off 7 Check engine oil Switch ON Safety Be careful Safety Be careful Do not use inside house Do not use inside house Read and understand the Owner Safety be careful Quick Reference Guide Quic...

Page 9: ...no part of the motor pump and of the machine in which it is integrated is moving and no pipes contain liquid under pressure a Turn off the delivery pressure as described in point a in Pump Operation...

Page 10: ...nd of the season or once a year Check and if necessary change the diaphragms Check the tightness of the motor pump screws Check the safety devices 8 Refer to the pump and engine manufacturer s manuals...

Page 11: ...ce spark plug Over choking Open choke and crank engine over Engine falters or not running smoothly Choke is opened too soon Close choke until engine runs smoothly Engine shuts down during operation Ou...

Page 12: ...lter dirty Clean the filter Not enough water supply or priming too deep Make sure the water supply flow rate or priming depth is in compliance with the indications in the Model Information page 2 The...

Page 13: ...ts or materials of any parts upon return of the entire pump or other product or of the particular part to the Dual Pumps Ltd factory within the warranty period at the sole expense of the purchaser whi...

Page 14: ...hether the claim is valid and if so will issue a credit for the item Should Dual Pumps Ltd find the claimed item to be out of warranty declarations the said charge will stand and be paid by the custom...

Page 15: ...strial Estate Melton Mowbray Leicestershire LE13 1BS United Kingdom Person authorised to compile the technical file declaration Tom Herridge Product Manager Signed We hereby declare that the machine d...

Page 16: ...nit 8 Hudson Road Saxby Road Ind Est Melton Mowbray Leicestershire LE13 1BS Telephone 44 0 1664 567226 Fax 44 0 1664 410127 E mail info dualpumps co uk www dualpumps co uk pumps DP SW116PHR V1 0 09 22...

Reviews: