Signal Generator w/grounded output
+EX
-EX
-SIG
+SIG
+ID
-ID
Shield
3
1
2
6
7
5
4
−
EX
+ID
Æ
Internal to SLICE Bridge
Electronic ID
Interface
Excitation
5-volts 20 mA
+EX
3K
3K
−
ID
Half-Bridge Switch
Sensor Side
Å
+SIG
−
SIG
Amplifier
2.5V
Sig Gen
(grounded)
4.0 volts p-p
(add 2.5-volts
offset to signal)
Notes:
•
SLICE input range is 0-5 volts WRT SLICE power
ground and –Excitation.
•
Both sides of input amplifier must be connected
either externally or +Signal via ½ bridge mode.
•
Input range does not quite extend to 0 & 5
volts.
Best to use signals under 4.5-volts p-p.
Sample Sensor Settings
•
Desired Range = 2000
•
Sensitivity = 1.000 mV/EU
•
Units = mV
•
Sensor Type = Half-Bridge
•
Proportional to Excitation = No
•
Zero Type = None
•
Remove Offset = No